DSC-V1 (serv.man4) - Sony Digital Camera Service Manual (repair manual). Page 9

Read Sony DSC-V1 (serv.man4) Service Manual online

DSC-V1
6-7
COVER
COVER
1-2.
INITIALIZATION  OF  0E,  2F,  4F,  6F  PAGE
DATA
1-2-1.
Initialization of 0E, 2F, 4F, 6F Page Data
1.
Initializing 0E, 2F, 4F, 6F Page Data
Note 1:
Initialize the data every page of 0E, 2F, 4F, and 6F.
Note 2:
If the 4F page data has been initialized, the following
adjustments need to be performed again.
1) Video system adjustment
2) LCD system adjustments
Note 3:
If the 6F page data has been initialized, the following
adjustments need to be performed again.
1) Camera system adjustments
Adjusting Page
0E
Adjusting Address
00 to FF
Adjusting Page
2F
Adjusting Address
00 to 7F
Adjusting Page
4F
Adjusting Address
00 to FF
Adjusting Page
6F
Adjusting Address
00 to FF
Initializing Method:
1) Select page: 00, address: 01 and set data: 01.
2) Click 
[Page Edit]
 on the SEUS screen to display the SEUS
PAGE EDIT screen.
3) Click 
[Page]
, and then enter the page to be initialized.
4) Click 
[Preset Data Read]
 to display the Set ID input screen.
5) For page 0E, enter Set ID = “00” and read the initializing data
on the SEUS PAGE EDIT screen.
6) For page 2F, 4F and 6F, enter Set ID = “09” and read the ini-
tializing data on the SEUS PAGE EDIT screen.
7) On the SEUS PAGE EDIT screen, change the data at “Fixed
data-2” address given in the table on the page to be initialized.
Note:
New data for change are not listed in the table. If the
data are to be changed, read and copy the data from the
same model. Copying the data from different models
may cause an operation failure.
8) Confirm that the data at respective adjustment addresses are
the initial values (adjustment initial values) given in the table.
If different, change to the adjustment initial values.
9) Click 
[Write]
 to write the initializing data to the set.
10) Click 
[Close]
 to close the SEUS PAGE EDIT screen.
Processing after Completing Initializing
Order Page Address
Data
Procedure
1
20
00
29 
[set]
2
20
01
29 
[Write]
(Note)
Note:
At this time, the set is reset and the power is turns off once
and then on again. Accordingly, the message “Receive
Packet Error” is displayed on the SEUS screen, and the
SEUS goes in “disconnect” state, but this is not a trouble.
Click 
[Connect]
 on the SEUS screen to restore the “con-
nected” state. (In case that the power does not turn on again,
press the power button.)
2.
0E Page table
Note 1:
Fixed data-1: Initialized data.
(Refer to step 5 of “ 1. Initializing of 0E, 2F, 4F, 6F Page
Data”)
Note 2:
Fixed data-2: Modified data.
(Refer to step 7 of “ 1. Initializing of 0E, 2F, 4F, 6F Page
Data”)
Address
Initial value
Remark
00 to FF
Fixed data-1 (Initialized data)
3.
2F Page table
Note 1:
Fixed data-1: Initialized data.
(Refer to step 6 of “ 1. Initializing of 0E, 2F, 4F, 6F Page
Data”)
Note 2:
Fixed data-2: Modified data.
(Refer to step 7 of “ 1. Initializing of 0E, 2F, 4F, 6F Page
Data”)
Address
Initial value
Remark
00 to 20
Fixed data-1 (Initialized data)
21
00
Test mode
22 to 7F
Fixed data-1 (Initialized data)
4.
4F Page table
Note 1:
Fixed data-1: Initialized data.
(Refer to step 6 of “ 1. Initializing of 0E, 2F, 4F, 6F Page
Data”)
Note 2:
Fixed data-2: Modified data.
(Refer to step 7 of “ 1. Initializing of 0E, 2F, 4F, 6F Page
Data”)
Address
Initial value
Remark
00 to 81
Fixed data-1 (Initialized data)
82
90
VCO adj. (NTSC mode)
83
9B
VCO adj. (PAL mode)
84
91
V-COM adj.
85
B2
Bright adj.
86
2D
Black limit adj.
87
Fixed data-1 (Initialized data)
88
84
White balance adj.
89
66
8A
3F
Contrast adj.
8B to 9F
Fixed data-1 (Initialized data)
A0
80
Composite video level adj.
A1 to A7
Fixed data-1 (Initialized data)
A8
A9
Fixed data-2
AA to FF
Fixed data-1 (Initialized data)
Page of 39
Display

Click on the first or last page to see other DSC-V1 (serv.man4) service manuals if exist.