DSC-U20 (serv.man7) - Sony Digital Camera Service Manual (repair manual). Page 13

Read Sony DSC-U20 (serv.man7) Service Manual online

6-11
DSC-U20
2.
CAMERA Adjustment 2
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during Camera Adj.
2. F No. Compensation
3. Mechanical Shutter Adj.
4. Light Value Adj.
5. Mixed Color Cancel Data Input
6. AWB 3200K Data Input
7. AWB 3200K Check
8. AWB 5800K Data Input
9. AWB 5800K Check
10. Color Reproduction Data Input
11. CCD Linearity Check
12. Release of Data Setting during Camera Adj.
[Adjusting method]
1) Click the 
[CAMERA Adjustment 2 Start]
 button.
2) The Automatic Adjustment Program executes the “1. Data Set-
ting during Camera Adj.”.
3) Upon successful completion of the “1. Data Setting during
Camera Adj.”, the following message is displayed. Set the sub-
ject in accordance with the message.
(For the standard picture frame, refer to “1-4-4. Picture frame
setting” (page 6-13).)
Fig. 6-1-16
4) Click the 
[OK]
 button, and the items from “2. F No. Compen-
sation” to “7. AWB 3200K Check” will be executed.
5) Upon successful completion of the “7. AWB 3200K Check”,
the following message is displayed. Set the filter in accordance
with the message.
Fig. 6-1-17
6) Click the 
[OK]
 button, and the “8. AWB 5800K Data Input”
and “9. AWB 5800K Check” will be executed.
7) Upon successful completion of the “9. AWB 5800K Check”,
the following message is displayed. Set the filter in accordance
with the message.
Fig. 6-1-18
1-4-3.
Adjusting Method
1.
CAMERA Adjustment 1
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during Camera Adj.
2. HALL Adj.
3. Flange Back Adj.
4. Flange Back Check
5. Release of Data Setting during Camera Adj.
[Adjusting method]
1) Click the 
[CAMERA Adjustment 1 Start]
 button.
2) The Automatic Adjustment Program executes “1. Data Setting
during Camera Adj.” and “2. HALL Adj.”.
3) Upon successful completion of the “2. HALL Adj.”, the fol-
lowing message is displayed.
Set the subject in accordance with the message.
Fig. 6-1-14
4) Click the 
[OK]
 button, and “3. Flange Back Adj.”, “4. Flange
Back Check”, and “5. Release of Data Setting during Camera
Adj.” will be executed.
5) Upon successful completion of all items of the CAMERA Ad-
justment 1, the following message is displayed. Click the [OK]
button.
Fig. 6-1-15
Page of 23
Display

Click on the first or last page to see other DSC-U20 (serv.man7) service manuals if exist.