6-10
DSC-U20
1-4-2.
Adjustment Items of Camera System Adjust-
ment
The adjustment items of camera system adjustment are as listed in
Table 6-1-2. The Automatic Adjustment Program divides the ad-
justment items into three, camera adjustment 1-3. Clicking either
CAMERA Adjustment Start button allows the adjustment item
which corresponds to that button to be executed.
The adjustment conditions of the subject and filter vary depend-
ing on which item is adjusted. The Adjustment Program displays
an instruction for the subject and filter as a message during the
adjustment.
Button Name
Adjustment
Subject
Adjustment
Adjustment
Page
Address
HALL Adj.
Not required
6F
58 to 5D, 68
CAMERA Adjustment 1
Frange Back Adj.
Frange back adjustment chart
6F
18 to 1D, 20 to 2B,
(2.0m from front the lens)
3E, 52, 53
Frange Back Check
(Luminance: 300 to 400 lux)
6F
10 to 15
F No. Compensation
6F
5E to 64
Mechanical Shutter Adj.
Clear chart (Standard picture frame)
6F
B8 to D7
Light Value Adj.
6F
65 to 67
Mixed Color Cancel Data Input
Not required
6F
B0, B1
AWB 3200K Data Input
Clear chart (Standard picture frame)
6F
70 to 74, B2, B4
CAMERA Adjustment 2
AWB 3200K Check
AWB 5800K Data Input
Clear chart (Standard picture frame)
6F
7C to 7F,
Filter C14 for color temperature
A0 to A3, B3
AWB 5800K Check
correction
Color Reproduction Data Input
Not required
6F
A4 to AB
CCD Linearity Check
Clear chart (Standard picture frame)
6F
88 to 8F, 9A, 9B
CAMERA Adjustment 3
Strobe Adj.
Flash adjustment box
6F
B6, B7, DA to EF
Table 6-1-2
Page of 23