DSC-U20 (serv.man4) - Sony Digital Camera Service Manual (repair manual). Page 21

Read Sony DSC-U20 (serv.man4) Service Manual online

DSC-U20
6-19
12. CCD Linearity Check
Check that CCD output keeps being straight even ISO sensitivity
is changed.
Mode
CAMERA
Subject
Clear chart
(Standard picture frame)
Measurement Point
Data of page: 10, address: 08 and
09 (2byte data) (Note 2)
Data of page: 10, address: 0A and
0B (2byte data) (Note 2)
Adjustment Page
6F
Adjustment Address
88 to 8F, 9A and 9B
Specified value 1
D00 to FFF or 000 to 300
Specified value 2
D00 to FFF or 000 to 300
Specified value 3
D00 to FFF or 000 to 300
Specified value 4
D00 to FFF or 000 to 300
Specified value 5
B00 to FFF or 000 to 500
Specified value 6
B00 to FFF or 000 to 500
Note 1:
Check that the data of page: 60, address: 02 is “00”. If
not, press the RESET switch at the bottom of the set us-
ing a thin and long pin.
Note 2:
2byte data is upper 1byte data and lower 1byte data.
XX XX
Lower 1byte data
(Page: 10, address: 09 or 0B)
Upper 1byte data
(Page: 10, address: 08 or 0A)
Checking method:
Order Page Address
Data
Procedure
1
Perform “Data setting
during camera system
adjustment”
(Refer to page 6-10)
2
Perform “Picture frame
setting”
(Refer to page 6-10)
3
79
F3
[Read]
Note down the data
4
79
F3
66 
[Write]
5
79
EB
[Read]
Note down the data
6
79
EB
FF 
[Write]
7
60
37
25 
[Set]
8
60
01
0F 
[Write]
9
60
02
[Read]
Check the data changes
to “01”.
10
10
08
[Read]
Read the data
(Upper 1byte).
11
10
09
[Read]
Read the data
(Lower 1byte).
12
This 2byte data
(Note 2) is named D1.
13
10
0A
[Read]
Read the data
(Upper 1byte).
14
10
0B
[Read]
Read the data
(Lower 1byte).
Order Page Address
Data
Procedure
15
This 2byte data
(Note 2) is named D2.
16
75
9A
[Read]
Note down the data.
17
75
9A
84 
[Write]
18
60
37
23 
[Set]
19
60
01
0F 
[Write]
20
60
02
[Read]
Check the data changes
to “01”.
21
10
08
[Read]
Read the data
(Upper 1byte).
22
10
09
[Read]
Read the data
(Lower 1byte).
23
This 2byte data
(Note 2) is named D3.
24
Calculate S1 using
following equations.
(hexadecimal calcula-
tion)
S1 = D1 –  D3
25
Check that the S1
satisfies the specified
value 1.
26
10
0A
[Read]
Read the data
(Upper 1byte).
27
10
0B
[Read]
Read the data
(Lower 1byte).
28
This 2byte data
(Note 2) is named D4.
29
Calculate S2 using
following equations.
(hexadecimal calcula-
tion)
S2 = D2 – D4
30
Check that the S2
satisfies the specified
value 2.
31
60
01
00 
[Write]
32
75
10
[Read]
Note down the data.
33
75
10
FF 
[Write]
34
79
70
[Read]
Note down the data.
35
79
70
53 
[Write]
36
60
37
24 
[Set]
37
60
01
0F 
[Write]
38
60
02
[Read]
Check the data changes
to “01”.
39
10
08
[Read]
Read the data
(Upper 1byte).
40
10
09
[Read]
Read the data
(Lower 1byte).
41
This 2byte data
(Note 2) is named D5.
42
Calculate S3 using
following equations.
(hexadecimal calcula-
tion)
S3 = D1 – D5
Page of 36
Display