DSC-T900 (serv.man2) - Sony Digital Camera Service Manual (repair manual). Page 5

Read Sony DSC-T900 (serv.man2) Service Manual online

1-1
ENGLISH
JAPANESE
ENGLISH
JAPANESE
DSC-T900_L2
1. SERVICE  NOTE
1-1. PRECAUTION  ON  REPLACING  THE  SY-225  BOARD
RESTORE DATA
When you replace to the repairing board, get the acquire data from the former needed for the adjustment from.
Start the Adjust Manual in the Adjust Station and perform “RESTORE DATA” to get the data.
The data getting for this model is as follows.
• USB SERIAL No.
• Angular Velocity Sensor sensitivity adj. (Dp/Dy/Fpy Data)
• Wide Limit adj.
Note:
When you cannot read data from the former replace the same time SY-225 board and lens.
DESTINATION DATA
When you replace to the repairing board, the written destination data of repairing board also might be changed to original setting.
Start the Adjust Manual in the Adjust Station and execute the “DESTINATON DATA WRITE”.
USB SERIAL No.
The set is shipped with a unique ID (USB Serial No.) written in it.
This ID has not been written in a new board for service, and therefore it must be entered after the board replacement.
Start the Adjust Manual in the Adjust Station and execute the “USB SERIAL No. INPUT”.
Angular Velocity Sensor
When you replace to the reparing board, write down the sensitivity displayed on the angular velocity sensor (SE401).
Start the Adjust Manual in the Adjust Station and execute the “Angular velocity sensor sensitivity adj”, input the date written down.
Note:
The sensor sensitivity of SE401 of SY-225 board is written only repair parts.
1-2. PRECAUTION  ON  REPLACING  THE LENS
When replacing the lens, write down the PITCH/YAW data, FN
data and wide limit data given on the lens for service.
Start the Adjust Manual in the Adjust Station and execute the “Wide
Limit adj.” and the “Angular velocity sensor sensitivity adj”, input the
data written down.
Note:
The PITCH/YAW data, FN data and wide limit data of lens
are written only repair parts.
SY-225 BOARD (SIDE B)
SE401
YYY: YAW Sensor Sensitivity
PPP: PITCH Sensor Sensitivity
YYY
PPP
XX
YY
F
N
L
1
/L
2
Wide Limit Data (2-byte data)
XXYY
YAW data
PITCH/YAW Data
PITCH data
P.PP / Y.YY
FN Data
FN data
XX