DSC-S75 (serv.man4) - Sony Digital Camera Service Manual (repair manual). Page 78

Read Sony DSC-S75 (serv.man4) Service Manual online

5-32
5. Bright Adjustment (SY-68 Board)
Set the level of the VIDEO signal for driving the LCD to the speci-
fied value.
If deviated, the LCD screen image will be blackish or saturated
(whitish).
Mode
PLAY
Signal
Arbitrary
Measurement Point
Pin 9 of CN401 (VG)
External trigger: Pin 8 of CN401
(PANEL_COM)
Measuring Instrument
Oscilloscope
Adjustment Page
D
Adjustment Address
D0
Specified Value
A = 1.32 
±
 0.05 Vp-p
A
2H 
GAMMA1 limiter level
Pedestal
A: Between the pedestal and GAMMA1
 limiter level
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
4
10
01
3
4
F1
03
4
D
D0
Change the data and set the
voltage (A) to the specified value.
5
D
D0
Press PAUSE button.
6
D
D0
Read the data and this data is
named Dref.
7
Convert Dref to decimal
notation, and obtain Dref’.
(Note)
8
Calculate D
CE
’ and D
DE
’ using
following equations.
(decimal calculation)
D
CE
’ = Dref’ – 11
D
DE
’ = Dref’ + 24
9
Convert D
CE
’ and D
DE
’ to
hexadecimal numbers, and
obtain D
CE
 and D
DE
. (Note)
10
D
CE
D
CE
Press PAUSE button.
11
D
DE
D
DE
Press PAUSE button.
Note:
Refer to table 5-2-2. “Hexadecimal-decimal conversion
table”.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
4
F1
00
2
4
10
00
3
0
01
00
Fig. 5-1-21
Page of 96