Read Sony DSC-S75 (serv.man4) Service Manual online
5-19
6.
Mechanical Shutter Adjustment
Adjust the period which the mechanical shutter is closed, and com-
pensate the exposure.
pensate the exposure.
Mode
CAMERA
Subject
Clear chart
(Color reproduction adjustment
frame with the zoom lens at WIDE
end)
(Color reproduction adjustment
frame with the zoom lens at WIDE
end)
Adjustment Page
F
Adjustment Address
5A, 6C to 7F, D4 to D8
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 2:
Refer to “Picture Frame Setting” for YH and YL.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
Perform “Data setting during
camera system adjustments”.
(Refer to page 5-14)
camera system adjustments”.
(Refer to page 5-14)
3
6
2C
01
4
6
90
00
5
6
91
00
6
6
92
YL
(Note 2)
7
6
93
YH
(Note 2)
8
6
01
79
Press PAUSE button.
9
6
07
Check the data changes to “01”.
10
6
01
00
Press PAUSE button.
11
6
01
AD
Press PAUSE button. (Note 3)
12
6
02
Check the data changes to “01”.
13
6
AB
Check the data changes to “00”.
Note 3:
The adjustment data will be automatically input to page:
F, address: 5A, 6C to 7F and D4 to D8.
F, address: 5A, 6C to 7F and D4 to D8.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
6
2C
00
3
6
92
00
4
6
93
00
5
Release the data setting
performed at step 2 .
(Refer to page 5-14)
performed at step 2 .
(Refer to page 5-14)
6
0
01
00
5.
F No. Standard Data Input
Compensate the unevenness of the iris meter sensitivity.
Mode
CAMERA
Subject
Clear chart
(Color reproduction adjustment
frame with the zoom lens at WIDE
end)
(Color reproduction adjustment
frame with the zoom lens at WIDE
end)
Adjustment Page
F
Adjustment Address
29 to 2D
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
If not, turn the power of unit OFF/ON.
Note 2:
Refer to “Picture Frame Setting” for YH and YL.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
Perform “Data setting during
camera system adjustments”.
(Refer to page 5-14)
camera system adjustments”.
(Refer to page 5-14)
3
6
2C
01
4
6
90
00
5
6
91
00
6
6
92
YL
(Note 2)
7
6
93
YH
(Note 2)
8
6
01
79
Press PAUSE button.
9
6
07
Check the data changes to “01”.
10
6
01
00
Press PAUSE button.
11
6
01
BB
Press PAUSE button. (Note 3)
12
6
02
Check the data changes to “01”.
Note 3:
The adjustment data will be automatically input to page:
F, address: 29 to 2D.
F, address: 29 to 2D.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
6
2C
00
3
6
92
00
4
6
93
00
5
Release the data setting
performed at step 2 .
(Refer to page 5-14)
performed at step 2 .
(Refer to page 5-14)
6
0
01
00
Click on the first or last page to see other DSC-S75 (serv.man4) service manuals if exist.