DSC-RX100M3 (serv.man4) - Sony Digital Camera Service Manual (repair manual). Page 15

Read Sony DSC-RX100M3 (serv.man4) Service Manual online

DSC-RX100M3_L2
1-12
Installation
1.  Match the 1st Group Press Block of the 1 Group Frame Block Assy with the cabinet number of the 3 Group Frame Block Assy and install the 1 
Group Frame Block Assy while turning it clockwise.
Note 1:  If Ornamental Ring (A) and Barrier Block Assy is installed to 1 Group Frame Block Assy, remove them first.
Note 2:  Be careful not to lose the 1st Group Press Block.
Note 3:  When installing the 1 Group Frame Block Assy, stop turning it when the convex parts of the 1st Group Press Block and the 3 Group Frame Block Assy 
match.
 
1st Group Press Block
3 Group Frame Block Assy
Cavity number
1 Group Frame Block Assy
2.  Install the Straight Tube Block Assy matching its cabinet number with the flexible boards position of the 3 Group Frame Block Assy.
 
Cavity number
Straight Tube Block Assy
Flexible boards
1st/2nd/3rd group assy
Gap
3.  After turning the Straight Tube Block Assy counterclockwise about eight degrees to fully install it, turn the Straight Tube Block Assy clockwise 
to the maximum extent to fit the bayonet.
 
Straight Tube Block Assy
About 8
°
4  Attach the DC Motor Worm Assy and tighten two screws. And install the 1st/2nd/3rd group assy to the Stationary Tube matching the phase marks 
as shown in the figure.
Note 1:  When installing this assy, confirm that the convex parts of the 3 Group Frame Block Assy, 1 Group Frame Block Assy and the Cam Tube are shown below.
Note 2:  Confirm that the straight key of the 3 Group Frame Block Assy is fit in the groove of the Stationary Tub. If the straight key is not fit in the groove, repeat 
these steps from step 1.
 
1st/2nd/3rd group assy
3 Group Frame Block Assy
Straight Tube Block Assy
Cam Tube
Convex parts
Gear end
Straight Tube Block Assy
Stationary Tube
Fit to groove
DC Motor 
Worm Assy
5.  Install the Lubricating Block Assy (B)* and turn it clockwise to the maximum extent.
 
*) Use a Lubricating Block Assy (B) that was not installed in the unit.
 
Lubricating Block Assy (B)
6.  Pass the two flexible boards through the holes in the Stationary Tube.
 
Stationary Tube
SS flexible board
SH flexible board
7.  Turn the Lubricating Block Assy (B)* counterclockwise to the maximum extent.
 
*) Use a Lubricating Block Assy (B) that was not installed in the unit.
 
Lubricating Block Assy (B)
Page of 31
Display

Click on the first or last page to see other DSC-RX100M3 (serv.man4) service manuals if exist.