DSC-RX10 (serv.man2) - Sony Digital Camera Service Manual (repair manual). Page 4

Read Sony DSC-RX10 (serv.man2) Service Manual online

DSC-RX10_L2
1-1
1. SERVICE  NOTE
1-1.  PRECAUTION ON REPLACING THE SY-1027 BOARD
DESTINATION DATA
When you replace to the repairing board, the written destination data of repairing board also might be changed to original setting.
Start the Adjust Manual in the Adjust Station and execute the “DESTINATION DATA WRITE”.
RESTORE DATA
When you replace to the repairing board, get the data from the former one.
Start the Adjust Manual in the Adjust Station and perform “RESTORE DATA” to get the data. 
The data getting for this model is as follows.
• PRODUCT ID & USB SERIAL No.
• AWB adj
• Lens Data Carry
• Light Sensor Adj
USB Serial No. and Product ID
The unit is shipped after an ID (USB Serial No.) unique to each unit and an ID (Product ID) unique to each model have been written.
These IDs have not been written in a new board for service, and therefore they must be entered after the board replacement.
After the board has been replaced with a board for service, start the Adjust Manual in the Adjust Station and execute the “PRODUCT ID & USB 
SERIAL No. INPUT” and enter these IDs.
Note:  A newly entered Product ID is not always equal to the ID before board replacement. If the new ID differs from the previous ID, it may cause a difference 
from the ID registered by the customer.
Update of MAC Address
When a board that contains Wi-Fi has been replaced or when replacing a board that contains the main IC (CPU), the IC’s unique number (MAC ad-
dress) must be reloaded.
Perform the following procedure to reload the IC’s unique number (MAC address).
1.  Download the latest-version Adjust Manual.
2.  Install the downloaded Adjust Manual.
3.  Start the Adjust Manual, and execute “Wireless LAN check” on the ADJUST tab.
4.  Perform the following operations for the unit to initialize.
 MENU 
→   → [Reset Network Set.] → [OK] → ●
5.  Perform the following operations for the unit to display MAC address.
 MENU 
→   → [Disp MAC Address] → ●
6.  Confirm that the displayed MAC address has been updated.
Applicable parts
•  SY-1027 BOARD, COMPLETE (SERVICE)
•  WF-1002 BOARD, COMPLETE
Note: The LOAD AND WRITE function in ADJUSTMENT DATA BACKUP on the DATA tab in the Adjust manual overwrites all data of the unit.
 
Therefore, the MAC address updated during the above procedure is also overwritten.
Perform the above operations after all work has been done.
After the replacement and repair, the MAC address is changed, and thus the re-setting for connection devices is required. Accordingly, download the 
Flyer of WLAN Reset (Flyer of WLAN Reset_9834752[][].pdf) and print out it, and attach it to the set when returning the set to customer.
– ENGLISH –
Angular Velocity Sensor
When you replace to the repairing board, write down the sensitivity displayed on the angular velocity sensor (SE3100).
Start the Adjust Manual in the Adjust Station and execute the “Angular velocity sensor sensitivity ADJ”.
Type A:
Type B:
Y P
Y P
P: PITCH sensor sensitivity
Y: YAW sensor sensitivity
SY-1027 BOARD (SIDE B)
SE3100
Note: The sensor sensitivity of SE3100 of SY-1027 board is written only repair parts.
1-2.  NOTES ON REPLACING THE LENS
When replacing the lens, read the QR code given on the data sheet of the replacement lens for 
service.
Start the Adjust Manual and read the QR code using a QR code reader.
The read data is used for adjustment after replacement.
Select “Lens data carry” on the ADJUST tab of the Adjust Manual, and click the LOAD button 
to load the file.
QR code
Page of 28
Display

Click on the first or last page to see other DSC-RX10 (serv.man2) service manuals if exist.