DSC-R1 (serv.man4) - Sony Digital Camera Service Manual (repair manual). Page 7

Read Sony DSC-R1 (serv.man4) Service Manual online

6-5
DSC-R1_ADJ
Fig. 6-1-4
6-1. CAMERA  SECTION  ADJUSTMENTS
1-1.
PREPARATIONS BEFORE ADJUSTMENTS
1-1-1.
Preparations
1) Connect the equipment for adjustments according to Fig. 6-1-4.
2) Start up the application for adjustment (SEUS).
Note 1:
Before perform the adjustment, set the following data.
1) Select page: 40, address: 38 and set data: 00.
Note 2:
After completing all adjustments, reset the camera.
Fig. 6-1-3
Video system Adjustment
Osilloscope
Terminated
75 
Insert the Memory Stick
.
PC
OS: Windows 98/98SE/Me/2000/XP
RAM: 256MB or more recommended
USB: 2.0 recommended 
         (also compatible with 1.1)
         Two connectors are required.
Video (yellow)
Color monitor
AC IN
AC power adaptor
USB cable
(1-827-038-11)
HASP Key
To VIDEO OUT jack
 To DC IN jack
To USB connector
To USB 
connector
Pattern box
Front of the lens
L = About 5 cm (Zoom at WIDE end)
L = About 30 cm (Zoom at TELE end)
L
Camera