DSC-P52 (serv.man4) - Sony Digital Camera Service Manual (repair manual). Page 37

Read Sony DSC-P52 (serv.man4) Service Manual online

6-35
DSC-P52
6. V COM Level Adjustment (SY-91 board)
Set the V COM signal level to an appropriate level.
Note: Do either of “Adjustment without Using Oscilloscope” or
“Adjustment Using Oscilloscope”.
6-1. Adjustment without Using Oscilloscope
Mode
PLAY ( 
 )
Signal
Arbitrary
Measurement Point
Data of page: 40, address: 11, 12
Measuring Instrument
Adjustment Page
4F
Adjustment Address
87
Specified Value
1A0 to 1A8
Adjusting method:
Order Page Address Data
Procedure
1
00
01
01
Set the data.
2
40
F1
02
Write the data.
3
4F
02
03
Write the data.
4
40
10
00
Write the data.
5
40
10
80
Write the data.
6
40
11
Read the data, and this data is
named D
11A
.
7
40
12
Read the data, and this data is
named D
12A
.
8
40
10
81
Write the data.
9
40
11
Read the data, and this data is
named D
11B
.
10
40
12
Read the data, and this data is
named D
12B
.
11
Calculate D
A
 and D
B
 using
following equation.
(Hexadecimal calculation.)
(Note1)
D
A
 = (D
11A
 
×
 4+ D
12A
 / 40)
D
B
 = (D
11B
 
×
 4+ D
12B
 / 40)
12
Calculate the signal level using
following equation.
(Hexadecimal calculation.)
When D
A
   D
B
Signal level = D
A
 - D
B
When D
A
 < D
B
Signal level = D
B
 - D
A
13
When the signal level satisfies the
specified value proceed to step 16,
in case of others proceed to step
14.
14
4F
87
Change the data. (Note2)
15
4F
87
Write the data, and return to step
4.
16
4F
02
00
Write the data.
17
40
F1
00
Write the data.
18
00
01
00
Set the data.
Note1: When dividing D
12A
 or D
12B
 by 40. If there is a fraction below
decimal point, truncate it.
Note2: When the signal level is smaller than specified value, increase the
data.
6-2. Adjustment Using Oscilloscope
Mode
PLAY ( 
 )
Signal
Arbitrary
Measurement Point
CL803 (Pin wj of IC801) (VCOM)
Measuring Instrument
Oscilloscope
Adjustment Page
4F
Adjustment Address
87
Specified Value
A = 5.65 
±
 0.05V
Adjusting method:
Order Page Address Data
Procedure
1
00
01
01
Set the data.
2
40
F1
02
Write the data.
3
4F
02
03
Write the data.
4
4F
87
Change the data and set the
signal level (A) to the specified
value.
5
4F
87
Write the data.
6
4F
02
00
Write the data.
7
40
F1
00
Write the data.
8
00
01
00
Set the data.
Fig. 6-1-19.
A
2H
Page of 43
Display

Click on the first or last page to see other DSC-P52 (serv.man4) service manuals if exist.