DSC-P52 (serv.man4) - Sony Digital Camera Service Manual (repair manual). Page 35

Read Sony DSC-P52 (serv.man4) Service Manual online

6-33
DSC-P52
4. Bright Adjustment (SY-91 board)
Set the level of the VIDEO signal for driving the LCD to the specified
value. If deviated, the screen image will be blackish or saturated
(whitish).
Note: Do either of “Adjustment without Using Oscilloscope” or
“Adjustment Using Oscilloscope”.
4-1. Adjustment without Using Oscilloscope
Mode
PLAY ( 
 )
Signal
Arbitrary
Measurement Point
Data of page: 40, address: 11, 12
Measuring Instrument
Adjustment Page
4F
Adjustment Address
85
Specified Value
0D7 to 0DF
Adjusting method:
Order Page Address Data
Procedure
1
00
01
01
Set the data.
2
40
F1
08
Write the data.
3
4F
02
03
Write the data.
4
40
10
00
Write the data.
5
40
10
90
Write the data.
6
40
11
Read the data, and this data is
named D
11A
.
7
40
12
Read the data, and this data is
named D
12A
.
8
40
10
91
Write the data.
9
40
11
Read the data, and this data is
named D
11B
.
10
40
12
Read the data, and this data is
named D
12B
.
11
Calculate D
A
 and D
B
 using
following equation.
(Hexadecimal calculation.)
(Note1)
D
A
 = (D
11A
 
×
 4 + D
12A
 / 40)
D
B
 = (D
11B
 
×
 4 + D
12B
 / 40)
12
Calculate the signal level using
following equation.
(Hexadecimal calculation.)
When D
    D
B
Signal level = D
A
 – D
B
When D
A
 < D
B
Signal level = D
B
 – D
A
13
When the signal level satisfies the
specified value proceed to step 16,
in case of others proceed to step
14.
14
4F
85
Change the data. (Note2)
15
4F
85
Write the data, and return to step
4.
16
4F
02
00
Write the data.
17
40
F1
00
Write the data.
18
00
01
00
Set the data.
Note1: When dividing D
12A
 or D
12B
 by 40. If there is a fraction below
decimal point, truncate it.
Note2: When the signal level is smaller than specified value, increase the
data. (The data should be “00” to “3F”.)
4-2. Adjustment Using Oscilloscope
Mode
PLAY ( 
 )
Signal
Arbitrary
Measurement Point
CL802 (Pin ws of IC801) (VG)
Measuring Instrument
Oscilloscope
Adjustment Page
4F
Adjustment Address
85
Specified Value
A = 2.95 
±
 0.05V
Adjusting method:
Order Page Address Data
Procedure
1
00
01
01
Set the data.
2
40
F1
08
Write the data.
3
4F
02
03
Write the data.
4
4F
85
Change the data and set the
voltage (A) between the reversed
waveform pedestal and non-
reversed waveform pedestal to
the specified value. (Note1)
5
4F
85
Write the data.
6
4F
02
00
Write the data.
7
40
F1
00
Write the data.
8
00
01
00
Set the data.
Note1: The data should be “00” to “3F”.
Fig. 6-1-17.
Pedestal
Pedestal
2H
A
Page of 43