Read Sony DSC-P41 / DSC-P43 (serv.man4) Service Manual online
DSC-P41/P43
6-22
1-7.
INITIALIZATION OF DATA
1.
Initializing All Page Data
By performing the following procedure, data of all pages will be
initialized.
initialized.
Note:
If all page data have been initialized, all adjustments need
to be performed again.
to be performed again.
Initializing Method:
1) Select page: 00, address: 01 and set data: 01.
2) Click
1) Select page: 00, address: 01 and set data: 01.
2) Click
[Sector Write]
on the SEUS screen to display the SEUS
SECTOR WRITE screen.
3) Check that the SET ID is “05”.
4) Click
4) Click
[All]
of the ALL SELECT buttons to select all pages.
(Fig. 6-1-48 A)
5) Click
[Write]
to write the initializing data to the flash memory
of the camera.
6) Wait for 3 sec.
7) Click
7) Click
[Close]
to close the SEUS SECTOR WRITE screen.
8) Select page: 8E, address: 00 and set data: 20.
9) Click
9) Click
[Save]
on the SEUS screen.
10) Wait for more than 3 sec.
11) Select page: 80, address: 30, and check that the data is “00”.
11) Select page: 80, address: 30, and check that the data is “00”.
Processing after Completing Initializing
Order Page Address
Data
Procedure
1
20
00
29
[Set]
2
20
01
29
[Set]
(Note)
Note:
At this time, the camera is reset and the power is turns off
once and then on again. Accordingly, the message “Re-
ceive Packet Error” is displayed on the SEUS screen, and
the SEUS goes in “disconnect” state, but this is not a
trouble. Click
once and then on again. Accordingly, the message “Re-
ceive Packet Error” is displayed on the SEUS screen, and
the SEUS goes in “disconnect” state, but this is not a
trouble. Click
[Connect]
on the SEUS screen to restore
the “connected” state. (In case that the power does not turn
on again, press the power button.)
on again, press the power button.)
Fig. 6-1-48
2.
Initializing Single Page Data
By performing the following procedure, data of the page that you
want to initialize will be initialized.
want to initialize will be initialized.
Note 1:
If the 6E or 6F page data have been initialized, the fol-
lowing adjustment needs to be performed again.
1) Camera system adjustments
lowing adjustment needs to be performed again.
1) Camera system adjustments
Note 2:
If the 8F page data have been initialized, the following
adjustment needs to be performed again.
1) Video system adjustments
2) LCD system adjustments
adjustment needs to be performed again.
1) Video system adjustments
2) LCD system adjustments
Initializing Method:
1) Select page: 00, address: 01 and set data: 01.
2) Click
1) Select page: 00, address: 01 and set data: 01.
2) Click
[Sector Write]
on the SEUS screen to display the SEUS
SECTOR WRITE screen.
3) Check that the SET ID is “05”.
4) Click “All” of the option buttons of target page. (Fig. 6-1-48
4) Click “All” of the option buttons of target page. (Fig. 6-1-48
B
)
5) Click
[Write]
to write the initializing data to the flash memory
of the camera.
6) Wait for 3 sec.
7) Click
7) Click
[Close]
to close the SEUS SECTOR WRITE screen.
8) When 8E page is initialized, select page: 8E, address: 00 and
set data: 20.
9) Click
[Save]
on the SEUS screen.
10) Wait for more than 3 sec.
11) Select page: 80, address: 30, and check that the data is “00”.
11) Select page: 80, address: 30, and check that the data is “00”.
Processing after Completing Initializing
Order Page Address
Data
Procedure
1
20
00
29
[Set]
2
20
01
29
[Set]
(Note)
Note:
At this time, the camera is reset and the power is turns off
once and then on again. Accordingly, the message “Re-
ceive Packet Error” is displayed on the SEUS screen, and
the SEUS goes in “disconnect” state, but this is not a
trouble. Click
once and then on again. Accordingly, the message “Re-
ceive Packet Error” is displayed on the SEUS screen, and
the SEUS goes in “disconnect” state, but this is not a
trouble. Click
[Connect]
on the SEUS screen to restore
the “connected” state. (In case that the power does not turn
on again, press the power button.)
on again, press the power button.)
B
A
05