Read Sony DSC-P31 / DSC-P31M Service Manual online
5-16
DSC-P31/P31M
2.
Flange Back Adjustment
(Using the minipattern box)
(Using the minipattern box)
The inner focus lens flange back adjustment is carried out auto-
matically. In whichever case, the focus will be deviated during
auto focusing/manual focusing.
matically. In whichever case, the focus will be deviated during
auto focusing/manual focusing.
Mode
CAMERA
Subject
Siemens star chart with ND filter
for minipattern box (Note 1)
for minipattern box (Note 1)
Measurement Point
Check operation on monitor TV
Measuring Instrument
Adjustment Page
F
Adjustment Address
18 to 2B, 3E, 52, 53
Note 1:
Dark Siemens star chart.
Note 2:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
If not, turn the power of unit OFF/ON.
Preparations before adjustments:
1) The minipattern box is installed as shown in the following fig-
1) The minipattern box is installed as shown in the following fig-
ure.
Note 3:
The attachment lenses are not used.
2) Install the minipattern box so that the distance between it and
the front of lens of camera is less than 3 cm.
3) Make the height of minipattern box and the camera equal.
4) Check the output voltage of the regulated power supply is the
4) Check the output voltage of the regulated power supply is the
specified voltage
± 0.01 Vdc.
5) Check that the center of Siemens star chart meets the center of
shot image screen with the zoom lens at TELE end and WIDE
end respectively.
end respectively.
Specified voltage: The specified voltage varies according to the
minipattern box, so adjustment the power sup-
ply output voltage to the specified voltage writ-
ten on the sheet which is supplied with the mini-
pattern box.
ply output voltage to the specified voltage writ-
ten on the sheet which is supplied with the mini-
pattern box.
Minipattern box
Below 3 cm
Camera
Camera
table
Red (+)
Black (–)
Yellow (SENS +)
White (SENS –)
Black (GND)
Need not connected
Regulated power supply
Output voltage : Specified voltage
±
0.01 Vdc
Output current : more than 3.5 A
Fig. 5-1-15
Adjusting method:
Order Page Address Data
Procedure
1
Perform “Data setting during
camera system adjustment”.
(Refer to page 5-13)
camera system adjustment”.
(Refer to page 5-13)
2
6
01
13
Press PAUSE button.
3
6
01
27
Press PAUSE button.
(Note 4)
(Note 4)
4
6
02
Check the data changes to
“01”.
“01”.
5
F
3E
Check the data.
00: Normal
01 to FF: Defective
00: Normal
01 to FF: Defective
6
F
24
Check the data.
0A to 7F: Normal
00 to 09,
80 to FF: Defective
0A to 7F: Normal
00 to 09,
80 to FF: Defective
Note 4:
The adjustment data will be automatically input to page:
F, address: 18 to 2B, 3E, 52 and 53.
F, address: 18 to 2B, 3E, 52 and 53.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
Release the data setting
performed at step 1.
(Refer to page 5-13)
performed at step 1.
(Refer to page 5-13)
3
Perform “Flange Back
Check”.
Check”.
RadarW
RadarW
RadarW
RadarW
RadarW
Click on the first or last page to see other DSC-P31 / DSC-P31M service manuals if exist.