DSC-P10, DSC-P12 (serv.man4) - Sony Digital Camera Service Manual (repair manual). Page 17

Read Sony DSC-P10 / DSC-P12 (serv.man4) Service Manual online

DSC-P10/P12
6-15
1.
Flange Back Adjustment
(Using the minipattern box)
The flange back of inner focus lens is adjusted automatically. If
shifted, the auto focus is disordered.
Mode
CAMER
Subject
Siemens star chart with ND filter
for minipattern box (Note 1)
Measurement Point
Check operation on monitor TV
Measuring Instrument
Adjustment Page
6F
Adjustment Address
18 to 3E, 40 to 53
Specified value 1
00
Specified value 2
0A to 40
Note 1:
Dark Siemens star chart.
Note 2:
Check that the data of page: 60, address: 02 is “00”. If
not, press the RESET switch using a thin and long pin.
Caution:
If the video lens or SY-83 board was replaced, make a setting
by referring to “Precaution on Replacing the Video Lens or the
SY-83 Board” and then perform the adjustment.
Preparations before adjustments:
1) The minipattern box is installed as shown in the following fig-
ure.
Note 3:
The attachment lenses are not used.
Note 4:
Take care not to hit the mini-pattern box when ex-
tending the lens.
2) Install the minipattern box so that the distance between it and
the front of lens of camera is less than 3 cm.
3) Make the height of minipattern box and the camera equal.
4) Check the output voltage of the regulated power supply is the
specified voltage 
± 0.01 Vdc.
5) Check that the center of Siemens star chart meets the center of
shot image screen with the zoom lens at TELE end and WIDE
end respectively.
Specified voltage: The specified voltage varies according to the
minipattern box, so adjustment the power sup-
ply output voltage to the specified voltage writ-
ten on the sheet which is supplied with the mini-
pattern box.
Minipattern box
Below 3 cm
Camera
Camera 
table
Red (+)
Black (–)
Yellow (SENS +)
White (SENS –)
Black (GND)
Need not connected
Regulated power supply
Output voltage : Specified voltage 
±
 0.01 Vdc
Output current : more than 3.5 A
Fig. 6-1-13
Adjusting method:
Order Page Address
Data
Procedure
1
Perform “Data setting
during camera sysem
adjustment”.
(Refer to page 6-13)
2
60
01
13 
[Write]
3
60
01
27  
[Write]
(Note 5)
4
60
02
[Read]
Check the data changes
to “01”.
5
6F
3E
[Read]
Check that the data
satisfied the specified
value 1.
6
6F
24
[Read]
Check that the data
satisfied the specified
value 2.
7
60
01
00 
[Write]
8
60
01
25 
[Write]
9
Wait for 3 seconds.
Note 5:
 The adjustment data will be automatically input to page:
6F, address: 18 to 3E and 40 to 53.
Processing after Completing Adjustments:
Order Page Address
Data
Procedure
1
60
01
00 
[Write]
2
Perform “Flange Back
Check “.
[Precaution on Replacing the Video Lens or the SY-83
Board]
The DSC-P10/P12 uses the position sensor to detect the zoom po-
sition.
Accordingly, the zoom position will vary if the position data
changes due to the replacement of the video lens or the SY-83
board, thus causing the video lens to collide against the mecha-
nism end when the power is turned off.
Though the position data is calibrated at the “Flange Back Adjust-
ment”, add the following work when making an adjustment at the
replacement of video lens to prevent a collision of video lens.
When Replacing the Video Lens
1) With current video lens assembled, turn the power on, and set
the data of page: 6F, address: 3E to “FF”, then turn the power
off.
2) Replace the video lens with a new one, turn the power on, and
perform the “Flange Back Adjustment”.
Thus, new position data will be written.
When Replacing the SY-83 Board
1) Replace the SY-83 board with a new one, set the mode dial to
“PLAY”, turn the power on, and set the data of page: 6F,
address:3E to “FF”, then turn the power off.
2) Set the mode dial to “CAMERA”, turn the power on, and per-
form the “Flange Back Adjustment”.
Thus, new position data will be written.
Page of 37