4-6
DSC-KW1/KW11
OK: The adjustment is finished normally.
T
OB VAL:
R OFFS:
G OFFS:
B OFFS:
0x0aed
0x00cb
0x0946
FINISH
OK
Limit:0x96 - 0x15e
Fig. 4-3-5
The adjustment is complete.
Adjustment order
Screen display
4-3-2. OB Adjustment
The OB (Optically Black) Adjustment order is as follows.
Check that the camera is on the adjustment mode.
* For the setting procedure of the adjustment mode, refer to “4-1-5. Setting the Adjustment Mode” (Page 4-3).
Cover camera lens (All black). (Fig. 4-3-4)
Touch the Up, Down, Right or Left key to change selected item. Choose “OB CLBT (BLACK)”, 
touch the Set key, select “OK”, and touch the Set key to start.
* If the adjustment is disabled, refer to “4-1-6. Enabling the Adjustment” to enable the adjustment. (Page 4-3)
In case of the adjustment is finished normally, 
the adjustment completion indication appears 
on the screen. (Fig. 4-3-5)
Press the “Shutter” button to return to 
adjustment menu.
Finished normally.
Finished abnormally.
In case of the indication other than that shown in 
Fig. 4-3-5 appears on the screen, confirm the 
adjusting environment and readjust.
Confirm the indication
on the screen.
Camera
Equipment required: Cover camera lens  
                                 (All black)
Black cloth
Screen side
Lens side
Fig. 4-3-4