DSC-H1 (serv.man12) - Sony Digital Camera Service Manual (repair manual). Page 3

Read Sony DSC-H1 (serv.man12) Service Manual online

— 3 —
DSC-H1
&
 : Points added portion.
+
Precaution on Replacing the SY-127 board
The Repair Board has already been adjusted. Re-initialization or EVR data copy from the set before repair is not
required.
Perform “VIDEO OUT Default Data Check” mentioned below, and also the adjustment items necessary after SY Board
replacement.
VIDEO OUT Default Data Check
When you replace to the repairing board, the written data of repairing board also might be changed to original setteing
because of broadcast system (NTSC/PAL).
When the data has changed because of board replaceing etc, check the default data of VIDEO OUT if destination code is
right. If not, rewrite to the right value.
VIDEO OUT Default Data
Page
Address
Data
NTSC
PAL
4F
8D
00
01
4F
A2
00
01
Writing Method:
1) Select page: 00, address: 01 and set data: 01.
2) Select page: 4F, address: 8D, and set data: 00 (NTSC) or data: 01 (PAL).
3) Select page: 4F, address: A2, and set data: 00 (NTSC) or data: 01 (PAL).
4) Select page: 40, address: 38, and set data: 00.
5) Click 
[Save]
 on the SEUS screen.
6) Wait for more than 3 sec.
7) Select page: 80, address: 30, and check that the data is “00”.
8) Select page: 00, address: 01, and set data: 00.
Page of 5