1.
Setting the Test Mode
Page D
Address 21
Data
Function
00
Normal
01
Forced MOVIE mode power ON
02
Forced SCN mode power ON
03
Forced CAMERA PROGRAM mode power ON
04
Forced CAMERA mode power ON
08
Forced PLAY mode power ON
09
Forced SET UP mode power ON
• Before setting the data, select page: 0, address: 01, and set data:
01.
• For page D, the data set is recorded in the non-volatile memory
by  pressing the PAUSE button of the adjusting remote com-
mander.  In this case, take note that the test mode will not be
exited even when the main power is turned off.
• After completing adjustments/repairs, be sure to return the data
of this address to “00”, and press the PAUSE button of the ad-
justing remote commander.
Select page: 0, address: 01, and set data: 00.
Display on the
Bit values
Adjusting
bit3
bit2
bit1
bit0
remote
or
or
or
or
commander
bit7
bit6
bit5
bit4
0
0
0
0
0
1
0
0
0
1
2
0
0
1
0
3
0
0
1
1
4
0
1
0
0
5
0
1
0
1
6
0
1
1
0
7
0
1
1
1
8
1
0
0
0
9
1
0
0
1
A (A)
1
0
1
0
B (b)
1
0
1
1
C (c)
1
1
0
0
D (d)
1
1
0
1
E (E)
1
1
1
0
F (F)
1
1
1
1
Example:
  If “8E” is displayed on the adjusting remote com-
mander, the bit values for bit7 to bit4 are shown in the
A
 column, and the bit values for bit3 to bit0 are shown
in the B column.
0 : 00 : 00
Page
bit7 to bit4 discrimination
bit3 to bit0 discrimination
Address
Display on the adjustilng remote commander
B
A
2.
Bit Value Discrimination
Bit values must be discriminated using the display data of the ad-
justing remote commander for following items.  Use the table be-
low to discriminate if the bit value is “1” or “0”.
Page of 47