DSC-F77, DSC-FX77 (serv.man3) - Sony Digital Camera Service Manual (repair manual). Page 38

Read Sony DSC-F77 / DSC-FX77 (serv.man3) Service Manual online

DSC-F77/FX77
6-36
3.
VCO Adjustment (SY-81 Board)
Set the VCO free-run frequency. If deviated, the LCD screen will
be blurred.
Mode
PLAY
Signal
Arbitrary
Measurement Point
JL701 of SY-81 board (HDO)
Measuring Instrument
Frequency counter
Adjustment Page
A
Adjustment Address
82 (NTSC mode)
83 (PAL mode)
Specified Value
f = 15734 
± 100 Hz (NTSC mode)
f = 15625 
± 100 Hz (PAL mode)
Menu setting:
1) VIDEO OUT of SET UP setting
.........................    NTSC (NTSC mode)
(This adjustment must be performed in NTSC mode, so don’t
set the menu setting to “PAL” )
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
A
02
03
Press PAUSE button.
3
4
F1
13
4
A
82
Change the data and set the
frequency (f) to the NTSC
specified value.
5
A
82
Press PAUSE button.
6
4
1D
82
7
A
83
Change the data and set the
frequency (f) to the PAL
specified value.
8
A
83
Press PAUSE button.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
A
02
00
Press PAUSE button.
2
4
F1
00
3
4
1D
80
4
0
01
00
Fig. 6-1-18
A
2H
4. PSIG Level Adjustment (SY-81 Board)
Set the common electrode drive signal level of LCD to the speci-
fied value.
Mode
PLAY
Signal
Arbitrary
Measurement Point
JL702 of SY-81 board (PSIG)
Measuring Instrument
Oscilloscope
Adjustment Page
A
Adjustment Address
87
Specified Value
A = 5.00 
± 0.10 Vp-p
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
A
02
03
Press PAUSE button
3
4
F1
02
4
A
87
Change the data and set the PSIG
signal level (A) to the specified
value. (Note)
5
A
87
Press PAUSE button.
Note:
Adjust it between data 00 and 7F.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
A
02
00
Press PAUSE button
2
4
F1
00
3
0
01
00
Page of 47