Read Sony DSC-F77 / DSC-FX77 (serv.man3) Service Manual online
DSC-F77/FX77
6-32
Order Page Address Data
Procedure
16
6
01
00
Press PAUSE button.
17
6
01
67
Press PAUSE button.
18
Check the flashing.
19
6
02
Check the data changes to
“01”.
“01”.
20
6
01
00
Press PAUSE button.
21
6
01
67
Press PAUSE button.
22
Check the flashing.
23
6
02
Check the data changes to
“01”.
“01”.
24
6
01
00
Press PAUSE button.
25
6
01
B9
Press PAUSE button. (Note 6)
26
Check the flashing.
27
6
02
Check the data changes to
“01”.
“01”.
28
6
01
00
Press PAUSE button.
29
6
01
E7
Press PAUSE button.
30
Check the flashing.
31
6
02
Check the data changes to
“01”.
“01”.
32
Wait for 1 second.
EA
Check that the displayed data
33
F
EC
satisfies the Y level data
EE
specified value.
34
0
03
02
35
1
Check that the R-Y, B-Y level
data (Note 4) satisfies the
specified value.
data (Note 4) satisfies the
specified value.
Note 6:
The adjustment data will be automatically input to page:
F, address: B6, B7 and DB to EF.
F, address: B6, B7 and DB to EF.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
6
92
00
3
6
93
00
4
6
2C
00
5
6
6C
00
6
0
03
00
7
Release the data setting
performed at step 1.
(Refer to page 6-14)
performed at step 1.
(Refer to page 6-14)
20. Strobe White Balance Adjustment
RadarW
RadarW
RadarW
RadarW
RadarW
Adjust the white balance when the strobe light flashed.
Mode
CAMERA
Subject
Flash adjustment box (Note 3)
(50 cm from the front of lens)
(50 cm from the front of lens)
Measurement Point
Displayed data of page: 1 (Note
4) and page: F, address: E8, EA,
EC, EE
4) and page: F, address: E8, EA,
EC, EE
Measuring Instrument
Adjusting remote commander
Adjustment Page
F
Adjustment Address
B6, B7, DB to EF
Specified Value
Y level data: 03 to 09
R-Y level data:
FA to FF or 00 to 06 (Note 4)
B-Y level data:
FA to FF or 00 to 06 (Note 4)
R-Y level data:
FA to FF or 00 to 06 (Note 4)
B-Y level data:
FA to FF or 00 to 06 (Note 4)
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
If not, turn the power of unit OFF/ON.
Note 2:
Perform this adjustment in the Flash adjustment box.
Note 3:
Refer to “4. Preparing the Flash adjustment box”.
(See page 6-7)
(See page 6-7)
Note 4:
The right four digits of the page: 1 displayed data of the
adjusting remote commander.
adjusting remote commander.
1:XX:XX
B-Y level data
R-Y level data
R-Y level data
Note 5:
“Strobe White Balance Adjustment” is available only
once after the power is turned on. Turn the power off,
then on again if the adjustment is retried.
once after the power is turned on. Turn the power off,
then on again if the adjustment is retried.
Switch setting:
1) FLASH (Control button) .............. ON
1) FLASH (Control button) .............. ON
Adjusting method:
Order Page Address Data
Procedure
1
Perform “Data setting during
camera system adjustment”.
(Refer to page 6-14)
camera system adjustment”.
(Refer to page 6-14)
2
6
2C
01
3
6
92
FF
4
6
93
FF
5
6
6C
01
6
6
01
79
Press PAUSE button.
7
6
07
Check the data changes to
“01”.
“01”.
8
6
01
67
Press PAUSE button.
9
Check the flashing.
10
6
02
Check the data changes to
“01”.
“01”.
11
F
E8
Check that the displayed data
satisfies the Y level data
specified value.
satisfies the Y level data
specified value.
12
6
01
00
Press PAUSE button.
13
6
01
67
Press PAUSE button.
14
Check the flashing.
15
6
02
Check the data changes to
“01”.
“01”.
Click on the first or last page to see other DSC-F77 / DSC-FX77 (serv.man3) service manuals if exist.