Read Sony XVM-B62 Service Manual online
8
XVM-B62
SECTION 4
TEST MODE
Setting Method:
1. Turn off power.
2. While holding the TEST switch (S408) down for more than 5
1. Turn off power.
2. While holding the TEST switch (S408) down for more than 5
seconds, turn on power. Then, release the TEST switch (S408).
3. TEST MODE MENU is indicated.
Terminating Method:
Select the MENU No. 7, SOFT REST using the [MENU] button and
determine the selection using the [POWER] button.
Select the MENU No. 7, SOFT REST using the [MENU] button and
determine the selection using the [POWER] button.
The FOR FACTORY Mode:
The FOR FACTORY mode can be used to perform 12 different
adjustment items with the remote controller.
The FOR FACTORY mode can be used to perform 12 different
adjustment items with the remote controller.
1. Select the MENU No. 2, FOR FACTORY using the [MENU]
button and determine the selection using the [POWER] button.
2. The FOR FACTORY mode is now entered. The following items
are selected in turn by pressing the [POWER] button repeatedly.
3. For each item selected, adjust so that the adjustment value is
within the specified value range using the [INPUT/+] and
[DIMMER/--] buttons on the remote controller.
[DIMMER/--] buttons on the remote controller.
4. After adjustment, press the [MENU] button to determine the
adjustment value. Press the [MENU] button once more to change
to the next item.
to the next item.
5. After all necessary adjustments are completed, select EXIT
using the [MENU] button and press the [POWER] button to display
the MENU screen. Then, select No.7, SOFT REST using the
[MENU] button and determine the selection using the [POWER]
button to terminate the TEST mode.
the MENU screen. Then, select No.7, SOFT REST using the
[MENU] button and determine the selection using the [POWER]
button to terminate the TEST mode.
Com Gain
Y Gain
Black Limt
White Limt
R-Sub BRT
B-Sub BRT
R-Sub CONT
B-Sub CONT
Gamma1
Gamma2
VCO Free Run
H Pos
Click on the first or last page to see other XVM-B62 service manuals if exist.