Read Sony XR-F5100S Service Manual online
15
XR-F5100S
frequency counter
test tape
WS-48A
(3 kHz, 0 dB)
WS-48A
(3 kHz, 0 dB)
set
speaker out terminal
–
+
4
Ω
PB Head Azimuth Adjustment
– Set Upper View –
Tape Speed Adjustment
TAPE SPEED ADJUSTMENT
Setting:
Procedure:
1. Put the set into the FWD PB mode.
2. Adjust adjustment resistor for inside capstan motor so that
2. Adjust adjustment resistor for inside capstan motor so that
the reading on the frequency counter becomes in 3,015 Hz.
Specified Value: 2,940 to 3,090 Hz
Adjustment Location:
TUNER SECTION
Tuner section adjustments are done automatically in this set.