Read Sony XR-F5100S Service Manual online
14
XR-F5100S
SECTION 4
MECHANICAL ADJUSTMENTS
SECTION 5
ELECTRICAL ADJUSTMENTS
1. Clean the following parts with a denatured-alcohol-moistened
swab:
playback head
pinch roller
rubber belt
capstan
idler
2. Demagnetize the playback head with a head demagnetizer.
3. Do not use a magnetized screwdriver for the adjustments.
4. The adjustments should be performed with the power supply
3. Do not use a magnetized screwdriver for the adjustments.
4. The adjustments should be performed with the power supply
voltage (14.4 V) unless otherwise noted.
Note:
With this set, it is not necessary to apply suitable locking compound
to the parts after the azimuth adjustment.
to the parts after the azimuth adjustment.
•
Torque Measurement
Mode
Torque Meter
Meter Reading
2.46 – 5.39 mN
⋅m
Forward
CQ-102C
(25 – 55 g
⋅cm)
(0.35 – 0.76 oz
⋅inch)
Forward
0.15 – 5.39 mN
⋅m
Back Tension
CQ-102C
(1.5 – 4 g
⋅cm)
(0.02 – 0.06 oz
⋅inch)
2.46 – 5.39 mN
⋅m
Reverse
CQ-102RC
(25 – 55 g
⋅cm)
(0.35 – 0.76 oz
⋅inch)
Reverse
0.15 – 0.39 mN
⋅m
Back Tension
CQ-102RC
(1.5 – 4 g
⋅cm)
(0.02 – 0.06 oz
⋅inch)
4.91 – 14.70 mN
⋅m
FF, REW
CQ-201B
(50 – 150 g
⋅cm)
(0.69 – 2.08 oz
⋅inch)
•
Tape Tension Measurement
Mode
Tension Meter
Meter Reading
Forward
CQ-403A
more than 5.89 mN
◊m
(more than 69 g)
Reverse
CQ-403A
(0.69 – 2.08 oz
◊inch)
TAPE DECK SECTION
0 dB = 0.775 V
1. The adjustments should be performed in the order given in
this service manual.
2. The adjustments should be performed for both L-CH and
R-CH.
•
Test Tape
Type
Signal
Used for
P-4-A063
6.3 kHz, –10 dB
head azimuth Adjustment
WS-48A
3 kHz, 0 dB
Tape Speed Adjustment
PB HEAD AZIMUTH ADJUSTMENT
Procedure:
1. Put the set into the FWD PB mode.
2. Turn the screw and check the output peak value. Adjust the
screw so that the peak value in channels L and R coincides
within 3 dB.
within 3 dB.
3. Check the phase in the FWD PB mode.
4. Repeat the above adjustment for the REV PB mode.
5. Check that output level difference between FWD PB mode
5. Check that output level difference between FWD PB mode
and REV PB mode is within 4 dB.
Adjustment Location: See page 15
level
meter
test tape
P-4-A063
(6.3 kHz, –10 dB)
P-4-A063
(6.3 kHz, –10 dB)
set
speaker out terminal
4
Ω
+
–
–
screw
position
position
L-CH
peak
peak
within
3 dB
3 dB
output
level
level
L-CH
peak
peak
R-CH
peak
peak
within
3 dB
3 dB
angle
R-CH
peak
peak
test tape
P-4-A063
(6.3 kHz, –10 dB)
P-4-A063
(6.3 kHz, –10 dB)
L-CH
R-CH
speaker out terminal
oscilloscope
V
H
+ +
–
–
Screen pattern
in phase
good
wrong
45
°
90
°
135
°
180
°
4
Ω
4
Ω
set
Click on the first or last page to see other XR-F5100S service manuals if exist.