SECTION 5
ELECTRICAL ADJUSTMENTS
SECTION 4
MECHANICAL ADJUSTMENTS
Precaution
1. Clean the following parts with a denatured alcohol-moistened
1. Clean the following parts with a denatured alcohol-moistened
swab:
playback heads
pinch rollers
rubber belts
capstan
idlers
2. Demagnetize the playback head with a head demagnetizer.
3. Do not use a magnetized screwdriver for the adjustments.
4. The adjustments should be performed with the power supply
2. Demagnetize the playback head with a head demagnetizer.
3. Do not use a magnetized screwdriver for the adjustments.
4. The adjustments should be performed with the power supply
voltage (14.4 V) unless otherwise noted.
Note: With this set, it is not necessary to apply suitable locking com-
pound to the parts after the azimuth adjustment.
Torque Measurement
Mode
Torque meter
Meter reading
Forward
CQ-102C
2.46 – 5.39 mN • m
(25 to 55 g • cm)
(0.35 – 0.76 oz • inch)
Forward
Back Tension
Back Tension
CQ-102C
0.15 – 0.39 mN • m
(1.5 to 4 g • cm)
(0.02 – 0.06 oz • inch)
Reverse
CQ-102RC
2.46 – 5.39 mN • m
(25 to 55 g • cm)
(0.35 – 0.76 oz • inch)
Reverse
Back Tension
Back Tension
CQ-102RC
0.15 – 0.39 mN • m
(1.5 to 4 g • cm)
(0.02 – 0.06 oz • inch)
FF, REW
CQ-201B
4.91 – 14.70 mN • m
(50 to 150 g • cm)
(0.69 – 2.08 oz • inch)
Tape Tension Measurement
Mode
Tension meter
Meter reading
Forward
CQ-403A
more than 5.89 mN • m
(more than 60 g • cm)
(more than 2.12 oz • inch)
Reverse
CQ-403R
TAPE DECK SECTION
0 dB=0.775V
1. The adjustments should be performed in the order given in this
service manual.
2. The adjustments should be performed for both L-CH and R-CH.
• Test Tape
Type
Signal
Used for
P-4-A063
6.3 kHz, –10 dB
Head Azimuth Adjustment
WS-48A
3 kHz, 0 dB
Tape Speed Adjustment
PB HEAD AZIMUTH ADJUSTMENT
Procedure:
1. Put the set into the FWD PB mode.
Procedure:
1. Put the set into the FWD PB mode.
2. Turn the screw and check the output peak value. Adjust the
screw so that the peak value in channels L and R coincides
within 3 dB.
within 3 dB.
3. Check the phase in the FWD PB mode.
4. Repeat the above adjustment for the REV PB mode.
5. Check that output level difference between FWD PB mode and
5. Check that output level difference between FWD PB mode and
REV PB mode is within 4 dB.
Adjustment Location: See page 21
level
meter
test tape
P-4-A063
(6.3 kHz, –10 dB)
set
speaker out terminal
4
Ω
+
–
screw
position
L-CH
peak
within
3 dB
output
level
L-CH
peak
R-CH
peak
within
3 dB
angle
R-CH
peak
test tape
P-4-A063
(6.3 kHz, –10 dB)
L-CH
R-CH
speaker out terminal
oscilloscope
V
H
+ +
– –
Screen pattern
in phase
good
wrong
45
° 90 ° 135 ° 180 °
4
Ω
4
Ω
set