SECTION  5
ELECTRICAL  ADJUSTMENTS
SECTION  4
MECHANICAL  ADJUSTMENTS
Precaution
1.   Clean the following parts with a denatured alcohol-moistened 
swab: 
     
playback heads 
pinch rollers
     rubber belts 
capstan
     idlers
2.   Demagnetize the playback head with a head demagnetizer.
3.   Do not use a magnetized screwdriver for the adjustments.
4.   The adjustments should be performed with the power supply 
voltage (14.4 V) unless otherwise noted.
Note:  With this set, it is not necessary to apply suitable locking com-
pound to the parts after the azimuth adjustment.
Torque Measurement
Mode
Torque meter
Meter reading
Forward
CQ-102C
2.46 – 5.39 mN • m
(25 to 55 g • cm)
(0.35 – 0.76 oz • inch)
Forward
Back Tension
CQ-102C
0.15 – 0.39 mN • m
(1.5 to 4 g • cm)
(0.02 – 0.06 oz • inch)
Reverse
CQ-102RC
2.46 – 5.39 mN • m
(25 to 55 g • cm)
(0.35 – 0.76 oz • inch)
Reverse
Back Tension
CQ-102RC
0.15 – 0.39 mN • m
(1.5 to 4 g • cm)
(0.02 – 0.06 oz • inch)
FF, REW
CQ-201B
4.91 – 14.70 mN • m
(50 to 150 g • cm)
(0.69 – 2.08 oz • inch)
Tape Tension Measurement
Mode
Tension meter
Meter reading
Forward
CQ-403A
more than 5.89 mN • m
(more than 60 g • cm)
(more than 2.12 oz • inch)
Reverse
CQ-403R
TAPE  DECK  SECTION
0 dB=0.775V
1.  The adjustments should be performed in the order given in this 
service manual.
2.  The adjustments should be performed for both L-CH and R-CH.
• Test Tape
Type
Signal
Used for
P-4-A063
6.3 kHz, –10 dB
Head Azimuth Adjustment
WS-48A
3 kHz, 0 dB
Tape Speed Adjustment
PB  HEAD  AZIMUTH  ADJUSTMENT
Procedure:
1.  Put the set into the FWD PB mode.
2.  Turn the screw and check the output peak value.  Adjust the 
screw so that the peak value in channels L and R coincides 
within 3 dB.
3.  Check the phase in the FWD PB mode.
4.  Repeat the above adjustment for the REV PB mode.
5.  Check that output level difference between FWD PB mode and 
REV PB mode is within 4 dB.
Adjustment Location: See page 21
level
meter
test tape 
P-4-A063
(6.3 kHz, –10 dB)
set
speaker out terminal
4
Ω
+
screw
position
L-CH
peak
within
3 dB
output
level
L-CH
peak
R-CH
peak
within
3 dB
angle
R-CH
peak
test tape 
P-4-A063
(6.3 kHz, –10 dB)
L-CH
R-CH
speaker out terminal
oscilloscope
V
H
+ +
– –
Screen pattern
in phase
good
wrong
45
° 90 ° 135 ° 180 °
4
Ω
4
Ω
set
Page of 66