Read Sony MDX-C800REC (serv.man4) Service Manual online
5
Mode No.
(Focus Bias Adj.)
(Focus Bias Adj.)
Represents the
point B measurement
point B measurement
Indicates the C1 error rate
Mode No.
(Focus Bias Adj.)
(Focus Bias Adj.)
Represent the
point A measurement
point A measurement
Indicates the C1 error rate
Mode No.
(EF-B Adj.)
(EF-B Adj.)
Represents
EF adjustment
EF adjustment
Initial set value Value after
automatic
adjustment
adjustment
TRAVERSE ADJUSTMENT
Connection:
Procedure:
1. Connect an oscilloscope between TP (TE) and TP (VC).
2. Set the test mode. (See page 2.)
3. Insert the test disc TDYS-1 and press 5 key.
4. Press 3 key.
1. Connect an oscilloscope between TP (TE) and TP (VC).
2. Set the test mode. (See page 2.)
3. Insert the test disc TDYS-1 and press 5 key.
4. Press 3 key.
LCD display
5. The traverse is automatically adjusted. Verify that the waveform
of the oscilloscope meets the specified value.
6. If outside the specified value, use DISC + or DISC – to adjust
the waveform.
Pressing of DISC + or DISC – will cause the value after
automatic adjustment to be varied.
Pressing of DISC + or DISC – will cause the value after
automatic adjustment to be varied.
7. Press + > M key for 2 seconds to save the data set in steps
5 and 6.
After saving the data, verify that the initial set value is equal to
the value after automatic adjustment.
After saving the data, verify that the initial set value is equal to
the value after automatic adjustment.
8. Press 3 key. The traverse adjustment is completed.
+
–
–
oscilloscope
V: 0.5 V/div H: 10 ms/div
Input: DC mode
Input: DC mode
MD servo board
TP (TE)
TP (VC)
A
B
VC
(Traverse waveform)
Specification: A = B
FOCUS BIAS ADJUSTMENT
Procedure:
1. Set the test mode. (See page 2.)
2. Insert the continuously recorded disc (see page 3.) and press 5
1. Set the test mode. (See page 2.)
2. Insert the continuously recorded disc (see page 3.) and press 5
key.
3. Press 4 key and check the error rate in the current focus bias
setting.
LCD display
<Setting the focus bias point A>
4. Verify that the first digit of the C1 error rate are “0”. Then,
4. Verify that the first digit of the C1 error rate are “0”. Then,
press 4 key.
LCD display
5. Press DISC + key until the C1 error rate value reaches “1.00”
(Note 1).
6. Press + > M key for 2 seconds to save the data set in step
5.
<Setting the focus bias point B>
7. Press 4 key.
7. Press 4 key.
LCD display
8. Press DISC – key until the C1 error rate value reaches “1.00”
(Note 1).
9. Press + > M key for 2 seconds to save the data set in step
8.
10. Press 4 key.
LCD display
Mode No.
(Focus Bias Adj.)
(Focus Bias Adj.)
Represents the
initial measurement
initial measurement
Indicates the
C1 error rate
C1 error rate
Mode No.
(Focus Bias Adj.)
(Focus Bias Adj.)
Represents the
calculated
point C measurement
calculated
point C measurement
Indicates the C1 error rate
Click on the first or last page to see other MDX-C800REC (serv.man4) service manuals if exist.