Mode No.
(Focus Bias Adj.)
Represents the
point B measurement
Indicates the C1 error rate
Mode No.
(Focus Bias Adj.)
Represent the
point A measurement
Indicates the C1 error rate
Mode No.
(EF-B Adj.)
Represents
EF adjustment
Initial set value Value after
automatic
adjustment
TRAVERSE ADJUSTMENT
Connection:
Procedure:
1. Connect an oscilloscope between TP (TE) and TP (VC).
2. Set the test mode. (See page 2.)
3. Insert the test disc TDYS-1 and press  5  key.
4. Press  3  key.
LCD display
5. The traverse is automatically adjusted. Verify that the waveform
of the oscilloscope meets the specified value.
6. If outside the specified value, use   DISC +  or   DISC –   to adjust
the waveform.
Pressing of   DISC +   or   DISC –   will cause the value after
automatic adjustment to be varied.
7. Press   + > M   key for 2 seconds to save the data set in steps
5 and 6.
After saving the data, verify that the initial set value is equal to
the value after automatic adjustment.
8. Press  3  key. The traverse adjustment is completed.
+
oscilloscope
V: 0.5 V/div   H: 10 ms/div
Input: DC mode
MD servo board
TP (TE)
TP (VC)
A
B
VC
(Traverse waveform)
Specification: A = B
FOCUS BIAS ADJUSTMENT
Procedure:
1. Set the test mode. (See page 2.)
2. Insert the continuously recorded disc (see page 3.) and press  5
key.
3. Press  4  key and check the error rate in the current focus bias
setting.
LCD display
<Setting the focus bias point A>
4. Verify that the first digit of the C1 error rate are “0”. Then,
press  4  key.
LCD display
5. Press   DISC +   key until the C1 error rate value reaches “1.00”
(Note 1).
6. Press   + > M   key for 2 seconds to save the data set in step
5.
<Setting the focus bias point B>
7. Press  4  key.
LCD display
8. Press   DISC –   key until the C1 error rate value reaches “1.00”
(Note 1).
9. Press   + > M   key for 2 seconds to save the data set in step
8.
10. Press  4  key.
LCD display
Mode No.
(Focus Bias Adj.)
Represents the
initial measurement
Indicates the
C1 error rate
Mode No.
(Focus Bias Adj.)
Represents the
calculated
point C measurement
Indicates the C1 error rate