MDX-C800REC (serv.man4) - Sony Car Audio Service Manual (repair manual). Page 4

Read Sony MDX-C800REC (serv.man4) Service Manual online

4
KMS-263A
2 7 X 9 3
B 0 8 2 5
(Optical pick-up label)
In this case, Iop = 82.5 mA
Iop (mA) = Reading on the digital voltmeter (mV)/1 (
)
  For the measurement points, see page 7.
LASER POWER ADJUSTMENT
Connection:
Procedure:
<Setting the write power reference value>
1. Connect a digital voltmeter between TP (I+3V) and TP (IOP).
2. Set the test mode. (See page 2.)
3. Insert a laser power meter into the disc insertion port and press  5
key.
4. Press  2  key.
LCD display
+
optical pick-up
objective lens
laser power
meter
digital voltmeter
MD servo board
TP (I+3V)
TP (IOP)
5. Use   DISC +   or   DISC –   key to adjust so that the reading on
the laser power meter is 6.9 to 7.1 mW.
6. Press   + > M   key for 2 seconds to save the data that has
been set in step 5.
7. Verify that the digital voltmeter reads out the specified value.
Specified value:
Reading on the digital voltmeter: Optical pick-up label indication
value ±10%
Mode No.
(LD Power Adj.)
7.0 mW power
<Setting the read power reference value>
8. Press  2  key.
LCD display
9. Use   DISC +   or   DISC –   key to adjust so that the reading on
the laser power meter is 0.69 to 0.71 mW.
10. Press   + > M   key for 2 seconds to save the data that has
been set in step 9.
11. Press  2  key.
LCD display
Mode No.
(LD Power Adj.)
0.7 mW power
12. Verify that the reading on the laser power meter is 6.0 to 6.4
mW.
If outside the specified value, adjust again from step 1.
13. Press  2  key. The laser power adjustment is completed.
Mode No.
(LD Power Adj.)
Main beam conversion power
Page of 8
Display

Click on the first or last page to see other MDX-C800REC (serv.man4) service manuals if exist.