Pin No.
Pin Name
I/O
Function
47
UNIREQ
O
Data request signal output terminal (for SONY bus)    “H”: request on    Not used (open)
48
UNCKI
I
Serial data transfer clock signal input from the master controller (IC700) (for SONY bus)
49
UNISI
I
Serial data input from the SONY bus interface (IC600)
50
UNISO
O
Serial data output to the SONY bus interface (IC600)
51
MD-CKO
O
Serial data transfer clock signal output to the CXD2652AR (IC301) and CXA2523R (IC302)
52
MD-SI
I
Reading serial data signal input from the CXD2652AR (IC301)
53
NCO
O
Not used (open)
54
SENS
I
Internal status (SENSE) input from the CXD2652AR (IC301)
55
CC-XINT
I
Interrupt status input from the CXD2652AR (IC301)
56
LIMIT-IN
I
Detection input from the sled limit-in detect switch (S903)
The optical pick-up is inner position when “L”
57
EJT-KEY
I
Eject request signal input terminal    “L”: eject on    Not used (fixed at “H”)
58
ERROR-PWM
O
PWM error monitor output terminal (C1and ATER is output when test mode)    Not used (open)
59
MD-RST
O
Reset signal output to the CXD2652AR (IC301) and BH6511FS (IC303)    “L”: reset
60
BU-IN
I
Battery detect signal input from the SONY bus interface (IC600) and battery check circuit
“H”: battery on
61
BUS-ON
I
SONY bus on/off control signal input from the master controller (IC700)    “L”: bus on
62
SQSY
I
Subcode Q sync (SCOR) input from the CXD2652AR (IC301)
“L” is input every 13.3 msec    Almost all, “H” is input
63
C-SW
I
Inputs the disc loading start or disc eject completion detect switch (S901) detection signal
“L”: When start or eject completed of the disc loading operation
64
MD-LAT
O
Serial data latch pulse signal output to the CXD2652AR (IC301) and CXA2523R (IC302)
65
MD-ON
O
Power supply on/off control signal output of the MD mechanism deck section main power supply
“H”: power on
66
DEEMP
O
Emphasis on/off control signal output terminal    “H”: emphasis on    Not used
67
A-MUTE
O
Audio muting on/off control signal output terminal    Not used
68
NCO
O
Not used (open)
69
TSTCKO
O
Output of clock signal for the test mode display    Not used (open)
70
TSTSO
O
Output of data for the test mode display    Not used (open)
71
TSTMOD
I
Setting terminal for the test mode    “L”: test mode, “H”: normal mode
72
VCC
Power supply terminal (+5V)
73
NC
Not used (fixed at “H”)
74 to 77
TOUT0 to TOUT3
O
Output of the 4
×
8 matrix test keys     Not used (open)
78 to 80
TIN0 to TIN2
I/O
Input of the 4
×
8 matrix test keys (“L” is always output, except in test mode)     Not used (open)
*1  Loading motor (M903) control
LOAD (pin 6)
“H”
“L”
“H”
“L”
EJECT (pin 7)
“L”
“H”
“H”
“L”
Terminal
Operation
IN
OUT
BRAKE
STOP
Page of 47