SECTION 1
SERVICING NOTES
UNLEADED SOLDER
Boards requiring use of unleaded solder are printed with the lead-
free mark (LF) indicating the solder contains no lead.
(Caution: Some printed circuit boards may not come printed with
Boards requiring use of unleaded solder are printed with the lead-
free mark (LF) indicating the solder contains no lead.
(Caution: Some printed circuit boards may not come printed with
the lead free mark due to their particular size)
: LEAD FREE MARK
Unleaded solder has the following characteristics.
• Unleaded solder melts at a temperature about 40 °C higher
• Unleaded solder melts at a temperature about 40 °C higher
than ordinary solder.
Ordinary soldering irons can be used but the iron tip has to be
applied to the solder joint for a slightly longer time.
applied to the solder joint for a slightly longer time.
Soldering irons using a temperature regulator should be set to
about 350 °C.
Caution: The printed pattern (copper foil) may peel away if
about 350 °C.
Caution: The printed pattern (copper foil) may peel away if
the heated tip is applied for too long, so be careful!
• Strong
viscosity
Unleaded solder is more viscous (sticky, less prone to fl ow)
than ordinary solder so use caution not to let solder bridges
occur such as on IC pins, etc.
than ordinary solder so use caution not to let solder bridges
occur such as on IC pins, etc.
• Usable with ordinary solder
It is best to use only unleaded solder but unleaded solder may
also be added to ordinary solder.
also be added to ordinary solder.
ABOUT CHECKING THE OPERATION
When checking the operation of this unit, connect a USB device
to this unit.
Refer to the support site written in the operating instruction for the
details about the compatibility of a USB device.
When checking the operation of this unit, connect a USB device
to this unit.
Refer to the support site written in the operating instruction for the
details about the compatibility of a USB device.
Cleaning the connectors
The unit may not function properly if the
connectors between the unit and the front
panel are not clean. In order to prevent this,
detach the front panel and clean the
connectors with a cotton swab. Do not apply
too much force. Otherwise, the connectors
may be damaged.
connectors between the unit and the front
panel are not clean. In order to prevent this,
detach the front panel and clean the
connectors with a cotton swab. Do not apply
too much force. Otherwise, the connectors
may be damaged.
Notes
t For safety, turn off the ignition before cleaning
the connectors, and remove the key from the
ignition switch.
ignition switch.
t Never touch the connectors directly with your
fingers or with any metal device.
NOTE THE MAIN BOARD OR SYSTEM CONTROLLER
(IC101) REPLACING
When the MAIN board or system controller (IC101) is replaced,
the destination setting is necessary.
(IC101) REPLACING
When the MAIN board or system controller (IC101) is replaced,
the destination setting is necessary.
1. Destination Setting
Set destination according to the procedure below.
Set destination according to the procedure below.
1-1. Setting the Destination Code
1. In the state of source off (the clock is displayed), enter the
1. In the state of source off (the clock is displayed), enter the
test mode by pressing the buttons on the remote commander in
order of the [4] t [5] t [6] (press only the [6] button for two
order of the [4] t [5] t [6] (press only the [6] button for two
seconds).
2. In the state in which the system controller version is displayed
on the liquid crystal display, enter the destination setting mode
by pressing the buttons on the main unit in order of the [SEEK
+] t [SEEK –] t [PUSH ENTER/SELECT].
by pressing the buttons on the main unit in order of the [SEEK
+] t [SEEK –] t [PUSH ENTER/SELECT].
3. Input the alphanumeric character of 6 digits of “F XXXXXX”
displayed on the liquid crystal display, and execute the destina-
tion setting.
tion setting.
Note: Refer to following “1-3. Entering the Destination Code” for opera-
tion method.
4. The resetting operation is executed by pressing the [SOURCE/
OFF] button for 1 second after the setting ends, and the unit
returns to the normal condition.
returns to the normal condition.
1-2. Display in Destination Setting Mode
8 digits
OP0
OP2 OP1
OP3
OP4
OP5
X
X
X
X
X
X
F
1-3. Entering the Destination Code
• Method of operation by main unit
• Method of operation by main unit
1. Rotate the control dial, and select the alphanumeric character
of “0 to F”.
2. The digit advances by pressing the [PUSH ENTER/SELECT]
or [SEEK +] button.
The digit returns by pressing the [ ] or [SEEK –] button.
3. The setting is completed by pressing the [PUSH ENTER/
SELECT] button, and the initialization operation is done.
• Method of operation by remote commander
1. Press the [ ] or [ ] button, and select the alphanumeric char-
acter of “0 to F”.
2. The digit advances by pressing the [
] button.
The digit returns by pressing the [
] button.
3. The setting is completed by pressing the [ENTER] button, and
the initialization operation is done.
1-4. Destination Code
Model
Destination
OP5 OP4 OP3 OP2 OP1 OP0
DSX-A30
AEP, Russian, UK
0
0
4
2
0
1
E, Mexican, Indian
0
0
4
A
0
0
Saudi Arabia
0
0
4
A
0
4
Argentina
0
0
4
A
0
3
DSX-A30E Russian
0
0
6
2
0
7
2. Confi rmation After Destination Setting
Execute the following operation after completing the destination
setting, and confi rm a correct destination was set.
Execute the following operation after completing the destination
setting, and confi rm a correct destination was set.
Destination setting checking method:
1. In the state of source off (the clock is displayed on the liquid
1. In the state of source off (the clock is displayed on the liquid
crystal display), enter the test mode by pressing the buttons on
the remote commander in order of the [4] t [5] t [6] (press
the remote commander in order of the [4] t [5] t [6] (press
only the [6] button for two seconds).
2. In the state in which the system controller version is displayed
on the liquid crystal display, enter the destination setting value
display mode by pressing the [DSPL] button on the main unit.
display mode by pressing the [DSPL] button on the main unit.
3. Confi rm the alphanumeric character of 6 digits of “F
XXXXXX” displayed in liquid crystal display is an value cor-
rectly input.
rectly input.
4. The resetting operation is executed by pressing the [SOURCE/
OFF] button on the main unit for 1 second after the confi rming
ends, and the unit returns to the normal condition.
ends, and the unit returns to the normal condition.
Ver. 1.4