CDX-656/656X
Tracking Offset Check
Connection:
– RF Board (Component Side) –
Procedure:
1. Connect the oscilloscope to TP (TE) and TP (VC) on the RF
1. Connect the oscilloscope to TP (TE) and TP (VC) on the RF
board.
2. Put the set into play mode by loading the disc (YEDS-18).
3. Press the . , > buttons on the master unit, and check the
3. Press the . , > buttons on the master unit, and check the
traverse waveform*.
4. Confirm that the oscilloscope waveform is symmetrical on the
top and bottom in relation to 0 V dc, and check this level.
* Traverse waveform: This is the tracking error wave form appears
when crossing the track.
oscilloscope
(DC range)
+
–
–
TP (VC)
TP (TE)
IC101
A
B
0 V
A=B
traverse waveform
(100 track jump waveform)
(100 track jump waveform)
VOLT/DIV: 500 mV
TIME/DIV: 2 ms
Center: 0 V
TIME/DIV: 2 ms
Center: 0 V
Traverse waveform