SECTION 4
MECHANICAL ADJUSTMENTS
Tape Tension Measurement
1. Clean the following parts with a denatured-alcohol-moistened
swab:
record/playback/erase head
pinch roller
capstan
rubber belt
2. Demagnetize the record/playback/erase head with a head demag
netizer.
3. Do not use a magnetized screwdriver for the adjustments.
4. The adjustments should be performed with the rated power supply
4. The adjustments should be performed with the rated power supply
voltage (3 V) unless otherwise noted.
Mode
Torque Meter
Meter Reading
1.97 – 3.92mN•m
FWD
(20 – 40 g•cm)
CQ-102C
(0.28 – 0.55 oz•inch)
FWD
Back Tension
Back Tension
0.05 – 0.49 mN•m
REV
(0.5– 5 g•cm)
REV
(0.007 – 0.069 oz•inch)
Back Tension
FF, REW
CQ-201B
more than 4.91 mN•m
(more than 50 g•cm)
(more than 0.69 oz•inch)
Mode
Tension Meter
Meter Reading
FWD
CQ-403A
more than 50 g
(more than 1.76 oz)
Torque Measurement
SECTION 5
ELECTRICAL ADJUSTMENTS
Tape Speed Adjustment
Mode: playback
Mode: playback
Procedure:
1. Set [DPC] switch (S401) off and [REC TIME] switch (S601) to
NORMAL (4.8 cm/s) position, and playback the tape (WS-48A) .
2. Adjust RV601 so that frequency counter reading becomes 3,010
Hz.
3. Set [REC TIME] switch (S601) to DOUBLE (2.4 cm/s) posi-
tion.
4.Playback the tape from the beginning for two minutes, then ad-
just RV602 so that frequency counter reading becomes 1,505 Hz.
1. Set [DPC] switch (S401) off and [REC TIME] switch (S601) to
NORMAL (4.8 cm/s) position, and playback the tape (WS-48A) .
2. Adjust RV601 so that frequency counter reading becomes 3,010
Hz.
3. Set [REC TIME] switch (S601) to DOUBLE (2.4 cm/s) posi-
tion.
4.Playback the tape from the beginning for two minutes, then ad-
just RV602 so that frequency counter reading becomes 1,505 Hz.
Confirm that deflection of the frequency counter reading between the
beginning and the end of tape is within 2% (NORMAL: approx. 60
Hz, DOUBLE: approx. 30 Hz) .
beginning and the end of tape is within 2% (NORMAL: approx. 60
Hz, DOUBLE: approx. 30 Hz) .
Setting:
• Supplied voltage: 3 V (DC)
• Switch and control position
• Supplied voltage: 3 V (DC)
• Switch and control position
VOL contorl (RV301)
: mechanical center
REC SPEED switch (S601) : normal (4.8cm/s)
PAUSE switch (S307)
PAUSE switch (S307)
: OFF
SPEED CONTROL (RV604) : center click
VOR switch (S501)
VOR switch (S501)
: OFF
0 dB=0.775 V
Type
Signal
Used for
WS-48A
3 kHz, 0 dB
tape speed adjustment
frequency
counter
counter
test tape
WS-48A
(3 kHz, 0 dB)
WS-48A
(3 kHz, 0 dB)
16 Ω
EAR jack (J302)
set
+
–
–
Test Tape
Regulation Level
input level
Mic
–60dBs
output level
earphone
16k
Ω, –22.4dBs
Adjustment Location:
– MAIN BOARD (Conductor Side) –
IC605
10
11
RV601
RV602
Tape Speed Adjustment
Tape Speed Adjustment
(Normal Speed)
(Double Speed)
RV401
DPC Adjustment
1
20
DPC Adjustment
PRECAUTION: Perform this adjustment before tape speed adjust
PRECAUTION: Perform this adjustment before tape speed adjust
ment.
setting:
DPC switch (S401) : ON
Tape speed
DPC switch (S401) : ON
Tape speed
: Noemal (4.8cm/s)
Mode
: Play
Adjustment Location:
– MAIN BOARD (Conductor Side) –
Q408
Q406
Q403
BCE
ECB
ECB
12
13
24
25
36
37
48
1
IC401
C431
C428
C427
C424
C438
C426
C425
C423
C422
C421
D406
D402
R402
R431
R420
R421
R421
R423
R419
R419
R410
R407
C408
C407
C416
C418
C429
433
C401
3
R406
R403
TP27
R409
R401
R408
R416
R422
R415
R414
R411
R
405
C411
C414
C430
C412
C413
V401
02
L401
+
–
–
TP27
frequency
counter
counter
Procedure:
1. Connect the frequency counter to the test point TP27 on the MAIN
1. Connect the frequency counter to the test point TP27 on the MAIN
board.
2. Adjust RV401 so that frequency counter reading becomes 230 Hz.
Standard value : 227 - 233Hz
Standard value : 227 - 233Hz