SECTION 3
TEST MODE
COLD RESET
Execute this mode when returning the unit to the customers.
Execute this mode when returning the unit to the customers.
Note 1: The main unit corresponding to the TA-SA400WR, wireless
transceivers (EZW-RT50 (except Chinese model) or EZW-RT20
(Chinese model)) (2 units) and the remote commander corre-
sponding to the main unit are necessary to execute this mode.
(Chinese model)) (2 units) and the remote commander corre-
sponding to the main unit are necessary to execute this mode.
Procedure:
1. Insert the wireless transceiver (EZW-RT50 (except Chinese
1. Insert the wireless transceiver (EZW-RT50 (except Chinese
model) or EZW-RT20 (Chinese model)) of the attachment in
the wireless transceiver slot in the back of the main unit and
the TA-SA400WR.
the wireless transceiver slot in the back of the main unit and
the TA-SA400WR.
Wireless transceiver
(EZW-RT50 (except Chinese model)
or EZW-RT20 (Chinese model))
(EZW-RT50 (except Chinese model)
or EZW-RT20 (Chinese model))
Wireless transceiver
(EZW-RT50 (except Chinese model)
or EZW-RT20 (Chinese model))
(EZW-RT50 (except Chinese model)
or EZW-RT20 (Chinese model))
Rear panel of the main unit
Rear panel of the TA-SA400WR
2. Connect the AC power cord of the main unit.
3. Press
3. Press
[\/1] button on the main unit to turn the power on.
4. Connect the AC power cord of the TA-SA400WR.
5. When wireless transmission is activated, the [LINK/STAND-
5. When wireless transmission is activated, the [LINK/STAND-
BY] indicator of the TA-SA400WR turns green.
LINK/STANDBY indicator
– Front view –
6. Press the button in order of the [DISPLAY]
[0] [7] [2]
[SUBTITLE] on the remote commander corresponding to
main unit aiming at the main unit
main unit aiming at the main unit
(Make the interval when each button is pressed within two sec-
onds).
onds).
7. Confi rm the [LINK/STANDBY] indicator of the TA-SA400WR
turns orange after step 6 is executed.
8. The AC power cord of TA-SA400WR is pulled out to turn the
power off.
Note
2: Insert it after confi rming the [LINK/STANDBY] indicator of
the
TA-SA400WR has been turned the power off when you
insert the AC power cord again.
2-5. WLK5_MAIN BOARD
2-6. POWER BOARD
1 connector
(CN901)
(CN901)
2 connector (CN300)
9 three claws
0 slot card (WLK4)
qa WLK5_MAIN board
8
7 four screws
(BV3)
(BV3)
6 two screws
(BV3)
(BV3)
4 two screws
(BV3)
(BV3)
5 heat sink (AMP)
3 Remove the cable from the hook.
2 connector
(CN901)
(CN901)
6 label fuse (T.H)
1 power cord connector
(CN900)
(CN900)
7 POWER board
3 four screws
(BV3)
(BV3)
4 PC board holder
5
power cord
cord bushing
60 ± 5 mm
to POWER
board
board