2
Supplied accessories
• 
Operating Instructions
• 
Quick Setup Guide
• 
GUI Menu List
• 
FM wire antenna (aerial) (1)
• 
AM loop antenna (aerial) (1)
• 
Remote control (1)
–  RM-AAP061 (US and CND models only)
–  RM-AAP062 (Other models)
• 
R6 (size AA) batteries (2)
• 
Optimizer microphone (ECM-AC2) (1)
Design and specifi cations are subject to change without notice.
Halogenated fl ame retardants are not used in the certain printed 
wiring boards.
• Abbreviation
AUS  : Australian model
CND : Canadian model
ECE  : Continental European, East European and Russian  
   
  models
TW  : Taiwan model
NOTES ON CHIP COMPONENT REPLACEMENT
• 
Never reuse a disconnected chip component.
• 
Notice that the minus side of a tantalum capacitor may be 
damaged by heat.
SAFETY CHECK-OUT
After correcting the original service problem, perform the follow-
ing safety check before releasing the set to the customer:
Check the antenna terminals, metal trim, “metallized” knobs, 
screws, and all other exposed metal parts for AC leakage.
Check leakage as described below.
LEAKAGE TEST
The AC leakage from any exposed metal part to earth ground and 
from all exposed metal parts to any exposed metal part having a 
return to chassis, must not exceed 0.5 mA (500 microamperes.). 
Leakage current can be measured by any one of three methods.
1.  A commercial leakage tester, such as the Simpson 229 or RCA 
WT-540A. Follow the manufacturers’ instructions to use these 
instruments.
2.  A battery-operated AC milliammeter. The Data Precision 245 
digital multimeter is suitable for this job.
3.  Measuring the voltage drop across a resistor by means of a 
VOM or battery-operated AC voltmeter. The “limit” indication 
is 0.75 V, so analog meters must have an accurate low-voltage 
scale. The Simpson 250 and Sanwa SH-63Trd are examples 
of a passive VOM that is suitable. Nearly all battery operated
digital multimeters that have a 2 V AC range are suitable.
(See Fig. A)
1.5 k
Ω
0.15 
μF
AC 
voltmeter 
(0.75 V) 
To Exposed Metal 
Parts on Set 
Earth Ground
Fig. A.  Using an AC voltmeter to check AC leakage.
SAFETY-RELATED COMPONENT WARNING!
COMPONENTS IDENTIFIED BY MARK 
0 OR DOTTED LINE  
WITH MARK 
0 ON THE SCHEMATIC DIAGRAMS AND IN 
THE PARTS LIST ARE CRITICAL TO SAFE OPERATION.
REPLACE THESE COMPONENTS WITH SONY PARTS 
 
WHOSE PART NUMBERS APPEAR AS SHOWN IN THIS 
 
MANUAL OR IN SUPPLEMENTS PUBLISHED BY SONY.
ATTENTION AU COMPOSANT AYANT RAPPORT  
À LA SÉCURITÉ!
LES COMPOSANTS IDENTIFIÉS PAR UNE MARQUE 
0 SUR 
LES DIAGRAMMES SCHÉMATIQUES ET LA LISTE DES 
P I È C E S   S O N T   C R I T I Q U E S   P O U R   L A  S É C U R I T É   D E 
FONCTIONNEMENT. NE REMPLACER CES COMPOSANTS 
QUE PAR DES PIÈCES SONY DONT LES NUMÉROS SONT 
DONNÉS DANS CE MANUEL OU DANS LES SUPPLÉ-
MENTS PUBLIÉS PAR SONY.
Page of 104
Display