HISTORY MODE
* The state that the set is used is memorized.
* Procedure:
1.  While depressing the [TUNING –]  and the [2CH/A.DIRECT] 
buttons simultaneously, press the [
?/1
] button to turn on the 
main power.
2. “HISTORY” 
appears.
3.  Each time the [↑] / [↓] buttons on the remote commander is 
pressed, the item is switched in order as follows.
Items
Protector Count
COUNT XX
Total single power on time
SXXXHXXM
Sound Field
SND FLD
Input function
FUNCTION
Input Mode
INP MODE
Digital Select
DIGI IN 
Stream information
STREAM 
Signal confi guration
CO XXXXX
Headphones
HP  XXX
Volume
VOL XXX
Bass Setting
BASS XXX
Treble Setting
TREB XXX
Front Level Setting
F  XXX
Center Level Setting
CT XXX
Surround Left Level Setting
SL XXX
Surround Right Level Setting
SR XXX
Subwoofer Level Setting
SW XXX
Total power on time
TXXXHXXM
Muting Status
MUTE XXX
Power on counter  
 
(Rebox test mode)
P.W.   XXX
Protector Type
PRT XXXX
Temperature when protect
TEM XXXC
DCAC FACTORY TEST MODE 
(Except US, Canadian model)
DCAC Factory Test mode have two stages:
1.  DCAC DSP Data Line Checking
2.  DCAC board Checking
 
DSP Data Line
Check
Start
Pass
Pass
Auto Cal Mic
Check
END
Factory Test System Setup
 
 
SPK Front Left
DCAC MIC
Receiver
1. When 
power 
off:
 
Press the three buttons [INPUT MODE] + [MOVIE] +  [
?/1
].
 “DCAC
[]
FTM” appears.
 
Afterward, press the [DISPLAY] to start DCAC factory test 
mode.
1. DCAC DSP Data Line Checking
After press the [DISPLAY], DCAC Factory test mode will start, 
below display will show:
“DCAC
[][][]
x” x=1, 
2, 
3
If there is error happen, below display will show:
“ERR
[]
SD0x” x=1 
t D1501 or R1530 problem
 x=2 
t D1503 problem
 x=3 
t D1504 problem
2. DCAC board Checking
Connect front left speaker of the receiver and AUTO CAL micro-
phone. Turn [MASTER VOLUME] jog, there will be test tone 
sound output from front left speaker, and the display will change 
accordingly.
“AD
[]
-
[]
xxx” 
xxx=0 to 255 (depends on loudness of test tone)
Note:
When the value reaches more than 222, the test tone will muted 
(for production line checking). Thus, the AD value will drop to 0.
To check the AD value again, power off the receiver and re-enter 
the test mode.
Ver. 1.1
Page of 64
Display