STR-DE597
 ATENÇÃO COM OS COMPONENTES DE SEGURANÇA!!
COMPONENTES IDENTIFICADOS COM A MARCA 
0
 NOS
DIAGRAMAS ESQUEMÁTICOS E NA LISTA DE PEÇAS SÃO
CRÍTICOS PARA A SEGURANÇA. SOMENTE OS SUBSTITUA
POR PEÇAS NUMERICAMENTE IDENTIFICADAS NESSE
MANUAL OU EM SUPLEMENTO PUBLICADO PELA SONY.
1.5 k
0.15 
µ
F
Voltímetro 
de AC
(0.75 V)
Para peça de metal
exposta no aparelho
Terra
SAFETY  CHECK-OUT (US MODEL)
After correcting the original service problem, perform the follow-
ing safety check before releasing the set to the customer:
Check the antenna terminals, metal trim, “metallized” knobs, screws,
and all other exposed metal parts for AC leakage.
Check leakage as described below.
TESTE DE FUGA
A fuga do AC de alguma parte do metal exposta à terra e de todas
as partes do metal expostas que tenham um retorno ao chassis,
não deve exceder 0.5 mA (500 microampers.). A corrente de 
fuga pode ser medida por qualquer um dos três métodos.
1. Um aparelho medidor de fuga, como Simpson 229 ou RCA
WT-540A. Siga as instruções dos fabricantes para usar esses
instrumentos.
2. Um mili-amperímetro de AC operado a bateria. O multímetro
digital Data Precision 245 é adequado para esse serviço.
3. Medindo a queda de tensão através de um resistor por meio
de um multímetro ou de um voltímetro de AC operado a bateria. A
indicação de "limite" é de 0,75V, desse modo os medidores
analógicos precisam ter uma escala precisa de baixa tensão. O
Simpsom 250 e o Sanwa SH-63Trd são exemplos de multímetros
passivos apropriados. Quase todos os multímetros operados a 
bateria que tem uma faixa de 2 V são adequados. (Veja Fig. A)
Fig. A.  