STR-DE197 - Sony Audio Service Manual (repair manual). Page 2

Read Sony STR-DE197 Service Manual online

2
STR-DE197
AM tuner section
Tuning range
Models of area code US, CND
With 10-kHz tuning scale: 530 – 1,710 kHz
 4)
With 9-kHz tuning scale: 531 – 1,710 kHz
 4)
Models of area code AEP
With 9-kHz tuning scale: 531 – 1,602 kHz
Antenna
Loop antenna
Intermediate frequency
450 kHz
Usable sensitivity
50 dB/m (at 1,000 kHz or
999 kHz)
S/N
54 dB (at 50 mV/m)
Harmonic distortion
0.5 % (50 mV/m,
400 Hz)
Selectivity
     At 9 kHz:
35 dB
     At 10 kHz:
40 dB
4) You can change the AM tuning scale to 9 kHz or
10 kHz. After tuning in any AM station, turn off
the receiver. Hold down PRESET TUNING + and
press ?/1. All preset stations will be erased when
you change the tuning scale. To reset the scale to
10 kHz (or 9 kHz), repeat the procedure.
General
Power requirements
Area code
Power consumption
US, CND
120 V AC, 60 Hz
AEP
230 V AC, 50/60 Hz
Power consumption
Area code
Power consumption
US
190 W
CND
270 VA
AEP
210 W
Power consumption (during standby mode)
0.5 W
AC outlets
Area code
AC outlets
US, CND
1 switched, 120 W/1A MAX
AEP
1 switched, 100 W MAX
Dimensions
430 
× 132.5 × 302 mm
(17 
× 5 
1/4
 
× 11 
7/8
 inches)
including projecting parts
and controls
Mass (Approx.)
7.0 kg (15 lb 7 oz)
Supplied accessories
FM wire antenna (1)
AM loop antenna (1)
Remote commander RM-U185 (1)
R6 (size-AA) batteries (2)
Design and specifications are subject to change without
notice.
• Abbreviation
CND: Canadian model
1.5 k
0.15 
µ
F
AC
voltmeter
(0.75 V)
To Exposed Metal
Parts on Set
Earth Ground
Fig. A. Using an AC voltmeter to check AC leakage.
SAFETY  CHECK-OUT
After correcting the original service problem, perform the following
safety check before releasing the set to the customer:
Check the antenna terminals, metal trim, “metallized” knobs, screws,
and all other exposed metal parts for AC leakage. Check leakage as
described below.
LEAKAGE TEST
The AC leakage from any exposed metal part to earth ground and
from all exposed metal parts to any exposed metal part having a
return to chassis, must not exceed 0.5 mA (500 microamperes).
Leakage current can be measured by any one of three methods.
1. A commercial leakage tester, such as the Simpson 229 or RCA
WT-540A. Follow the manufacturers’ instructions to use these
instruments.
2. A battery-operated AC milliammeter. The Data Precision 245
digital multimeter is suitable for this job.
3. Measuring the voltage drop across a resistor by means of a VOM
or battery-operated AC voltmeter. The “limit” indication is 0.75
V, so analog meters must have an accurate low-voltage scale. The
Simpson 250 and Sanwa SH-63Trd are examples of a passive
VOM that is suitable. Nearly all battery operated digital
multimeters that have a 2V AC range are suitable. (See Fig. A)
SAFETY-RELATED  COMPONENT  WARNING!!
COMPONENTS  IDENTIFIED  BY  MARK  
0
  OR  DOTTED  LINE
WITH  MARK  
0
  ON  THE  SCHEMATIC  DIAGRAMS  AND  IN
THE  PARTS  LIST  ARE  CRITICAL  TO  SAFE  OPERATION.
REPLACE  THESE  COMPONENTS  WITH  SONY  PARTS  WHOSE
PART  NUMBERS  APPEAR  AS  SHOWN  IN  THIS  MANUAL  OR
IN  SUPPLEMENTS  PUBLISHED  BY  SONY.
ATTENTION AU COMPOSANT AYANT RAPPORT
 À LA SÉCURITÉ!!
LES COMPOSANTS IDENTIFIÉS PAR UNE MARQUE 
0
 SUR LES
DIAGRAMMES SCHÉMATIQUES ET LA LISTE  DES PIÈCES
SONT CRITIQUES POUR LA SÉCURITÉ DE FONCTIONNEMENT.
NE REMPLACER CES COMPOSANTS QUE PAR DES PIÈCES
SONY DONT LES NUMÉROS SONT DONNÉS DANS CE MANUEL
OU DANS LES SUPPLÉMENTS PUBLIÉS PAR SONY.