SECTION  3
ADJUSTMENTS
Setting:
BAND switch: AM
Connection:
For AM frequency coverage adjustment and FM frequency coverage check.
AM Section
digital
voltmeter
TP (VT)
Connection:
AM RF signal 
generator
30% amplitude modulation by 
400 Hz signal.
Output level: as low as possible
Put the lead-wire
antenna close to 
the set.
level meter
set
headphone jack (
i
)
16 
+
FM Section
FM RF signal
generator
22.5 kHz frequency deviation 
by 400 Hz signal.
Output level: as low as possible
0.01 
µ
F
TP (ANT)
FM VCO Adjustment
Setting:
BAND switch:
FM
FM SENS switch: DX
Procedure:
1.
Turn off the FM RF signal generator.
2.
Put a capacitor (100 
µF) between pin ws (IC201) and GND.
3.
Put a resistor (100 k
Ω) between TP (VCO) and GND.
4.
Tune the set to 87.5 MHz.
5.
Adjust RV201 for 19 kHz 
± 0.05kHz reading on the frequency
counter.
AM FREQUENCY  COVERAGE  ADJUSTMENT
Adjust for a reading on digital voltmeter.
 T201
531 kHz (530 kHz) [531 kHz]
1.3V 
± 0.1V
  Confirm
1,602 kHz (1,710 kHz) [1,710 kHz]
10 V or less
AM  TRACKING  ADJUSTMENT
Adjust for a maximum reading on level meter.
CT201
1485 kHZ (1480 kHz)
L201
585 kHz (590 kHz)
FM FREQUENCY  COVERAGE  CHECK
Check a reading on digital voltmeter.
  Confirm
87.5 MHz [76.0 MHz]
3.5V [0.9 V] or more
  Confirm
108.0 MHz
11V or less
FM TRACKING  ADJUSTMENT
Adjust for a maximum reading on level meter.
CT101, CT102
108.0 MHZ
L104
87.5 MHz [76.0 MHz]
(     ) : Panama model   [     ] : Tourist model
Connection:
frequency counter
TP (VCO)
Setting:
BAND switch:
FM
FM SENS switch: DX
Connection:
Adjustment Location
[MAIN BOARD]
(SIDE B)
[MAIN BOARD]
(SIDE A)
IC401
CN401
IC201
GND
TP(VCO)
GND
GND
TP(ANT)
TP(VT)
TP(pin 
ws
)
IC101
CT101
CT102
CT201
L201
L104
FM TRACKING
Adjustment
AM TRACKING
Adjustment
T201
AM FREQUENCY 
COVERAGE Adjustment
RV201
FM VCO
Adjustment