Read Sony SRF-M95 Service Manual online
SRF-M95
AEP Model
Chinese Model
E Model
Australian Model
Tourist Model
SERVICE MANUAL
FM STEREO/AM PLL SYNTHESIZED RADIO
SPECIFICATIONS
Ver 1.2 2002. 05
Time display: 24-hour system
Frequency range:
Frequency range:
Band
Frequency range
Channel step
FM
Panama model :
Except Panama, Tourist model :
87.5 - 108 MHz
0.1 MHz
AM
530 -1 710 kHz
10 kHz
FM
87.5 - 108 MHz
0.05 MHz
AM
531 -1 602 kHz
9 kHz
Tourist model :
FM
76.0 - 108 MHz
0.05 MHz
AM
531 -1 710 kHz
9 kHz
Output: 2 (headphones) jack (
∅ 3.5 mm, stereo
minijack)
Power output: 2.5 mW + 2.5 mW (at 10 % harmonic
distortion)
Power requirements: 1.5 V DC, one R03 (size AAA)
battery
Auto Power off function: Approx. 30 minutes, 60
minutes, 90minutes, 120 minutes, and off
Dimensions: Approx. 39
× 83.8 × 20.4 mm (w/h/d)
(Approx. 1
9
/
16
× 3
3
/
8
×
13
/
16
inches) incl.
projecting parts and controls
Mass: Approx. 57.5 g (2 oz.) incl. battery and the
Accessories supplied
Stereo headphones (1)
Stereo headphones (1)
headphones
Design and specifications are subject to change
without notice.
without notice.
Battery Life (Approx. hours)
When using
FM
AM
Sony alkaline LR03(size AAA) 40
54
Sony R03(size AAA)
18
26
Sony Corporation
Personal Audio Company
Published by Sony Engineering Corporation
Published by Sony Engineering Corporation
9-873-067-13
2002E1600-1
© 2002.05
2
SRF-M95
Notes on chip component replacement
• Never reuse a disconnected chip component.
• Notice that the minus side of a tantalum capacitor may be
• Notice that the minus side of a tantalum capacitor may be
damaged by heat.
Flexible Circuit Board Repairing
• Keep the temperature of soldering iron around 270˚C
during repairing.
• Do not touch the soldering iron on the same conductor of the
circuit board (within 3 times).
• Be careful not to apply force on the conductor when soldering
or unsoldering.
SECTION 1
GENERAL
This section is extracted
from instruction manual.
from instruction manual.
Setting the Clock
The time display of this clock is a 24-hour system.
1
Press POWER to turn off the power.
2
Press and hold down the jog lever for
more than 2 seconds until “0”starts
flashing.
more than 2 seconds until “0”starts
flashing.
3
Slide or keep sliding the jog lever up or
down to adjust the hour and press the
jog lever.
down to adjust the hour and press the
jog lever.
If you keep sliding the jog lever up or down,
the number changes rapidly.
0:00=midnight, 12:00=noon.
the number changes rapidly.
0:00=midnight, 12:00=noon.
4
Slide the jog lever up or down to adjust
the minutes and press the jog lever.
the minutes and press the jog lever.
“:” starts flashing and the clock starts
operating.
To set the current time exactly to the second,
adjust the minute and then press the jog lever
in time with a time signal (such as the
telephone time signal).
To cancel the setting, press MODE.
operating.
To set the current time exactly to the second,
adjust the minute and then press the jog lever
in time with a time signal (such as the
telephone time signal).
To cancel the setting, press MODE.
Note
Once you start setting the clock, you must perform each
step within 60 seconds, or the clock setting mode will be
cancelled.
step within 60 seconds, or the clock setting mode will be
cancelled.
POWER
Jog Lever
(selection/decision)
Molette (sélection/décision)
Palanca de lanzadera
(selección/decisión)
MODE
HOLD
MEGA BASS
Display Window
Afficheur
Visualizador
Afficheur
Visualizador
2
VOL
Front
Face avant
Parte frontal
Face avant
Parte frontal
3
SRF-M95
SECTION 2
DISASSEMBLY
Note :
Follow the disassembly procedure in the numerical order given.
2-1. MAIN BOARD, SUB BOARD
1
Screw (1.4
×
10)
1
Screw (1.4
×
10)
9
SUB board
7
Cover (Jack)
1
Screw (1.4
×
10)
5
Flexible board
4
Screw
6
MAIN board
3
Cabinet (front) assy
2
Six claws
8
Screw
4
SRF-M95
SECTION 3
ADJUSTMENTS
Setting:
BAND switch: AM
Connection:
BAND switch: AM
Connection:
For AM frequency coverage adjustment and FM frequency coverage check.
AM Section
digital
voltmeter
voltmeter
TP (VT)
Connection:
AM RF signal
generator
generator
30% amplitude modulation by
400 Hz signal.
Output level: as low as possible
400 Hz signal.
Output level: as low as possible
Put the lead-wire
antenna close to
the set.
antenna close to
the set.
level meter
set
headphone jack (
i
)
16
Ω
+
–
–
FM Section
FM RF signal
generator
generator
22.5 kHz frequency deviation
by 400 Hz signal.
Output level: as low as possible
by 400 Hz signal.
Output level: as low as possible
0.01
µ
F
TP (ANT)
FM VCO Adjustment
Setting:
BAND switch:
FM
FM SENS switch: DX
Procedure:
1.
Turn off the FM RF signal generator.
2.
Put a capacitor (100
µF) between pin ws (IC201) and GND.
3.
Put a resistor (100 k
Ω) between TP (VCO) and GND.
4.
Tune the set to 87.5 MHz.
5.
Adjust RV201 for 19 kHz
± 0.05kHz reading on the frequency
counter.
AM FREQUENCY COVERAGE ADJUSTMENT
Adjust for a reading on digital voltmeter.
T201
531 kHz (530 kHz) [531 kHz]
1.3V
± 0.1V
Confirm
1,602 kHz (1,710 kHz) [1,710 kHz]
10 V or less
AM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
CT201
1485 kHZ (1480 kHz)
L201
585 kHz (590 kHz)
FM FREQUENCY COVERAGE CHECK
Check a reading on digital voltmeter.
Confirm
87.5 MHz [76.0 MHz]
3.5V [0.9 V] or more
Confirm
108.0 MHz
11V or less
FM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
CT101, CT102
108.0 MHZ
L104
87.5 MHz [76.0 MHz]
( ) : Panama model [ ] : Tourist model
Connection:
frequency counter
TP (VCO)
Setting:
BAND switch:
BAND switch:
FM
FM SENS switch: DX
Connection:
Adjustment Location
[MAIN BOARD]
(SIDE B)
[MAIN BOARD]
(SIDE A)
IC401
CN401
IC201
GND
TP(VCO)
GND
GND
TP(ANT)
TP(VT)
TP(pin
ws
)
IC101
CT101
CT102
CT201
L201
L104
FM TRACKING
Adjustment
Adjustment
AM TRACKING
Adjustment
Adjustment
T201
AM FREQUENCY
COVERAGE Adjustment
AM FREQUENCY
COVERAGE Adjustment
RV201
FM VCO
Adjustment
FM VCO