SCD-XE800 - Sony Audio Service Manual (repair manual). Page 13

Read Sony SCD-XE800 Service Manual online

SCD-XE800
SCD-XE800
13
13
 
Manual Adjust
1. Track Balance Adjust:
2. Track Gain Adjust:
3. Focus Balance Adjust:
4. Focus Gain Adjust:
5. Eq Boost Adjust:
6. Iop: xx
7. TRV. Level:
8. S curve(FE) Level:
9. RFL(PI) Level:
0. MIRR Time:
[
V][v] Change Value
[RETURN]Return to previous menu
5.  Convert data from hexadecimal to decimal by using conver-
sion table.
6.  If the value is smaller than 93 (decimal), then it is OK. How-
ever if the value is higher than 93, then BU (base unit) is defec-
tive and need to be change.
7.  Press the [
O
 RETURN] button on the remote commander to 
return to previous menu.
8.  Press the [0] button on the remote commander to return to the 
top menu of Remocon Diagnosis Menu.
9.  Disconnect the power cord to turn off.
Note: Don’t press the [
?/1
] button when to release from this mode. Nec-
essarily disconnect the power cord. The set doesn’t operate when 
turning off power with [
?/1
] button of the set.
4.  Checking Emergency History
To check the emergency history, please follow the following pro-
cedure.
Procedure:
1.  From the top menu of Remocon Diagnosis Menu, select “3. 
Emergency History” by pressing the [3] button on the remote 
commander. The following screen appears on the on-screen 
display.
 
Emg. History Check
Laser Hours     CD    999h  59min
                DVD     0h   0min
01. 01 05 04 04      00 92 46 00
    00 00 00 00      00 00 23 45
02. 02 02 01 01      00 A9 4B 00
    00 00 00 00      00 00 23 45
[Next]Next page [Prev]Prev page
[0]Return to Top Menu
2.  You can check the total time when the laser is turned on during 
playback of Super Audio CD and CD from the above menu. 
The maximum time, which can be displayed are 999h 59min.
3.  You can check the error code of latest 10 emergency history 
from the above menu. To view the previous or next page of 
emergency history, press the [
.
] or [
>
] button on the re-
mote commander.
The error code consists of three kinds of error codes. 
A. Error code
Example of Error code
01. 01 05 04 04      00 92 46 00
    00 00 00 00      00 00 23 45
The meaning of error code is as below:
01: Communication error (No reply from syscon)
02: Syscon hung up
03: Power OFF request when syscon hung up
19: Thermal shutdown
24: MoveSledHome error
25: Mechanical move error (5 changer)
26: Mechanical move stack error
30: DC motor adjustment error
31: DPD offset adjustment error
32: TE balance adjustment error
33: TE sensor adjustment error
34: TE loop gain adjustment error
35: FE loop gain adjustment error
36: Bad jitter after adjustment
40: Focus NG
42: Focus layer jump NG
51: Spindle stop error
52: Open kick spindle error
60: Focus on error
61: Seek fail error
62: Read Q data/ID error
70: Lead in data read fail
71: TOC read time out (CD)
80: Can’t buffering
81: Unknown media type
B. Parameter of error code
This is the detail of error code. 
Example of Error code
01. 01 05 04 04      00 92 46 00
    00 00 00 00      00 00 23 45
C. Time of error code
This is the laser time when an error occurred.
Example of Error code
01. 01 05 04 04      00 92 46 00
    00 00 00 00      00 00 23 45
To Clear Laser Hours and Emergency History
Perform Step 6. for EEPROM CLEAR of SERVICE MODE (1).
Note: You will not be able to clear only one of either Laser Hours or Emer-
gency History. When EEPROM CLEAR is run, all content will be 
deleted.
Version information
Initialize all data...
Complete!
[0]Return to Top Menu
Emg. History Check
Laser Hours     CD      0h   0min
                DVD     0h   0min
01. 00 00 00 00      00 00 00 00
    00 00 00 00      00 00 00 00
02. 00 00 00 00      00 00 00 00
    00 00 00 00      00 00 00 00
[Next]Next page [Prev]Prev page
[0]Return to Top Menu
To Execute the Initialize Setup Data
Procedure:
1.  Press the [MENU] button on the remote commander and then 
press the [CLEAR] button on the remote commander. The fol-
lowing screen appears on the on-screen display.
 
Emg. History Check
Laser Hours     CD    999h  59min
                DVD     0h   0min
Initialize setup data...
[Next]Next page [Prev]Prev page
[0]Return to Top Menu
2.  The screen after a while returns to former display.
To Return to the Top Menu of  Remocon Diagnosis 
Menu
Press the [0] button on the remote commander.
5.  Checking Version Information
To check the version information, please follow the following pro-
cedure.
Procedure:
1.  From the top menu of  Remocon Diagnosis Menu, select “4. 
Version Information” by pressing the [4] button on the remote 
commander. The following screen appears on the on-screen 
display.
 
Version information
Firm(Main): Ver. X.XXXX
Firm(Sub): XX.XX
RISC: XXXXXX
8032: XXXXXX
Audio DSP: XX.XX.XX.XX
Servo DSP: XX.XX.XX.XX
[0]Return to Top Menu
2.  To return to the top menu of Remocon Diagnosis Menu, press 
the [0] on the remote commander.
Page of 48
Display

Click on the first or last page to see other SCD-XE800 service manuals if exist.