11
List of trouble log
Note: “nnn” of toggle article number is a generation frequency of the error.
Type
Test key 
(Remote commander)
Toggle article 
number
Content
Rebooting emergence 
(Rebooting emergence 
factor)
Test key2 (
R)
2Annn
It was not possible to communicate with MTK fi ve seconds more continu-
ously
2Bnnn
Compulsion power off demand was received from MTK
2Cnnn
Only MTK reset it 
(Destination, model and region for are the disagreements)
2Dnnn
Fails in the start of MTK
2Ennn
Fails in the switch of the input mode of MTK
2Fnnn
Input mode of MTK changed without permission
2Gnnn
Reacts to the key notifi cation no though the communication with MTK is 
alive
Serial communications 
(MTK communication 
error factor)
Test key3 (
t)
3Annn
It was not possible to communicate with MTK with 48ms
3Bnnn
A non-standard packet length was received (Excluding 16 bytes)
3Cnnn
Checksum NG
3Dnnn
Type of the communication header is NG
MTK power control 
(Power ON/OFF error 
factor)
Test key4 (
r)
4Annn
Fails in AC ON Initial
4Bnnn
Fails in power on of MTK
4Cnnn
Initialization response of CDM is abnormal
4Dnnn
CDM mechanism error notifi cation is received
4Ennn
Input mode is NG MTK is started
4Fnnn
MTK input mode switch at time fails usually
4Gnnn
Fails in power off of MTK
4Hnnn
Fails in power off of CDM