CHARGE  CONTROL  IC501  outputs  status  signals  shown  in  Table.2-4  while  charging.  In  this  unit,  only  XSTAT1  signal  is  used.  This  means  that  System  Controller  IC400 
monitors if IC501 is charging or not. 
 
Table.2-4 Status signal 
IC501 Pin-2 [XSTAT1] 
IC501 Pin-3 [XSTAT2] 
Status 
When pre-charging 
Open 
When normal-charging 
Open 
When the charging operation terminates 
Open 
Open 
Error Status 
 
Battery is not connected 
 
Detecting the abnormal temperature 
 
Detecting the timer fault 
Etc. 
 
Table.2-5 Monitoring the charging operation by SYSTEM CONTROLLER IC400 
IC400 Pin-85 [PF4] 
Status 
When charging 
When the charging operation terminates 
 
Table.2-6 Charging Current 
Power Source 
Pre-charging 
(Until BATT voltage becomes 3[V]) 
Constant-Current Charging 
Remark 
USB (500mA – Permit) 
Approx. 50mA 
Approx. 430mA 
Varies depending on conditions. The left 
values are when connecting with PC 
without transferring data 
USB (100mA – Permit) 
Approx. 50mA 
Approx. 90mA 
Varies depending on conditions.   
 
Note: 
 
The actual charging current of USB charge varies depending on the system conditions. It will be as follows.   
[Each VBUS limit current] – [Current consumed by the system] = [Actual charging current] 