NW-A1200 - Sony Audio Service Manual (repair manual). Page 16

Read Sony NW-A1200 Service Manual online

16
NW-A1200
8. “+X” is displayed. Main unit is fixed so that 1 of fig.1 may
become downward and press the [     ]
u
 key.
EL display
+X
9. “+Y” is displayed. Main unit is fixed so that 3 of fig.1 may
become downward and press the [     ]
u
 key.
EL display
+Y
10. “CALIB” is displayed. Press the [     ]
u
 key, G-sensor is adjusted.
Then “FIN”, “DAT NG” or “SEN NG” is displayed automatically.
(Press the [BACK]
 
key, return to minor item selection screens)
EL display
CALIB
r
FIN
FIN
: Normally completing.
DAT NG : The data for performing a calibration is faulty.
SEN NG : The value acquired from the G-sensor is faulty.
11. The offset and the sensitivity of each axis are displayed by
pressing the [     ]
u
 key when normally completing in order of X,
Y and Z.
EL display
*** ##
***
: offset, 
##:
sensitivity
12. Press the [BACK]
 
key, return to minor item selection screen.
5-3-6. G-sensor adjustment check
This mode checks that G-sensor adjustment is performed or not
performed.
Checking method:
1. Enter the test mode.
2. Press the
 
[  ]
B
 
key to display major item, and press the  [  ]
v
/ [  ]
V
key to select the “OTHERS”.
EL display
OTHERS
3. Press the
 
[  ]
B
 
key to display minor item, and press the  [  ]
v
/ [  ]
V
key to select the “G CHK”.
EL display
G CHK
4. Press the [     ]
u
 key, “START” is displayed. Then “OK” or “YET”
is displayed automatically.
EL display
START
r
OK
5. Press the [BACK]
 
key, return to minor item selection screen.
4
2
5
3
1
6
Fig.1   Axis direction of G-sensor adjustment
Page of 56
Display

Click on the first or last page to see other NW-A1200 service manuals if exist.