Read Sony MHC-V6D Service Manual online
MHC-V6D
5
CAPACITOR ELECTRICAL DISCHARGE PROCESSING
When checking the board, the electrical discharge is necessary for
the electric shock prevention.
Connect the resistor to both ends of respective capacitors.
When checking the board, the electrical discharge is necessary for
the electric shock prevention.
Connect the resistor to both ends of respective capacitors.
• D-AMP
board
CN1000 (pin 6 and 10, pin 6 and 3)
•
Switching regulator (SWR1)
C202, C203, C403, C407, C531 and C532
– Switching Regulator (Conductor Side) –
– D-AMP Board (Conductor Side) –
800
:/2 W
(for C403)
800
:/2 W
(for C407)
800
:/2 W
(for C531)
800
:/2 W
(for C532)
800
:/2 W
(for C203)
800
:/2 W
(for C202)
800
:/2 W
(pin 3 and 6)
800
:/2 W
(pin 6 and 10)
1
10
CN1000
MODEL IDENTIFICATION
Distinguish by Part No. and Destination code on the rear side of
a main unit.
Distinguish by Part No. and Destination code on the rear side of
a main unit.
– Rear View –
– Back Panel –
Part No.
Destination code
Part No.
Destination code
Destination
4-488-633-0[]
E4/SA2
African and South African
4-488-633-1[]
E12
Indian
4-488-633-2[]
E51
Chilean and Peruvian
4-488-633-3[]
E93
United Arab Emirates,
Kuwait, Iraq, Kenya,
Tanzania and Nigeria
Kuwait, Iraq, Kenya,
Tanzania and Nigeria
4-488-633-4[]
SP6
Singapore and Malaysia
4-488-633-5[]
TH1
Thai
4-488-633-6[]
MX4
Mexican
4-488-633-7[]
E2
120V AC area in E
Ver. 1.3