4-2. Check point in ARAGON board
27
System controller
Repair tips:
EVER+3.3V output for
System controller can be
checked at connecter
terminal. (CN304 pin1 and 2)
EVER+3.3V output for
System controller can be
checked at connecter
terminal. (CN304 pin1 and 2)
Repair tips:
13.5V output from SWR board
for System controller can be
checked at connecter
terminal (CN001 pin1 and 3)
13.5V output from SWR board
for System controller can be
checked at connecter
terminal (CN001 pin1 and 3)
Audio processor
Serial Flash for
Audio processor
Audio processor
DC/DC converter
for EVER +3.3V
for EVER +3.3V
USB HUB
controller
controller
Troubleshooting:
Remove this cable from SWR
board and connect AC plug of
MHC-V5 to a wall outlet.
If 13.5V output is not output
from SWR board, SWR board
is damaged.
Remove this cable from SWR
board and connect AC plug of
MHC-V5 to a wall outlet.
If 13.5V output is not output
from SWR board, SWR board
is damaged.
DC/DC converter
for 5V (USB/Motor)
for 5V (USB/Motor)
Thermistor
to check input air
from ventilator
to check input air
from ventilator