MDS-W1 - Sony Audio Service Manual (repair manual). Page 10

Read Sony MDS-W1 Service Manual online

– 10 –
Hexadecimal
Bit
Binary
Higher Bits
Lower Bits
8
4
2
1
8
4
2
1
b7 b6 b5 b4 b3 b2 b1 b0
0
0
0
0
0
0
0
1
0
0
0
0
0
0
1
0
0
0
0
0
0
1
0
0
0
0
0
0
1
0
0
0
0
0
0
1
0
0
0
0
0
0
1
0
0
0
0
0
0
1
0
0
0
0
0
0
1
0
0
0
0
0
0
0
Hexa-
decimal
Details
01
02
04
08
10
20
40
80
Emphasis OFF
Monaural
This is 2-bit display. Normally 01.
01:Normal audio. Others:Invalid
Audio (Normal)
Original
Copyright
Write prohibited
When 0
When 1
Emphasis ON
Stereo
Invalid
Digital copy
No copyright
Write allowed
Reading the Display:
Convert the hexadecimal display into binary display. If more than
two causes, they will be added.
Example
When 84 is displayed:
Higher bit : 8 = 1000 n b7
Lower bit : 4 = 0100 n b2
In this case, as b2 and b7 are 1 and others are 0, it can be
determined that the retry cause is combined of “emphasis OFF”,
“monaural”, “original”, “copyright exists”, and “write allowed”.
Example
When 07 is displayed:
Higher bit : 0 = 1000 n All 0
Lower bit : 7 = 0111 n b0+b1+b2
In this case, as b0, b1, and b2 are 1 and others are 0, it can be
determined that the retry cause is combined of “emphasis ON”,
“stereo”, “original”, “copyright exists”, and “write prohibited”.
Hexadecimal 
n
 Binary Conversion Table
Hexadecimal
Binary
Hexadecimal
Binary
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
0000
0001
0010
0011
0100
0101
0110
0111
1000
1001
1010
1011
1100
1101
1110
1111
Reading the Track Mode Display
Hexadecimal
Bit
Binary
Higher Bits
Lower Bits
8
4
2
1
8
4
2
1
b7 b6 b5 b4 b3 b2 b1 b0
0
0
0
0
0
0
0
1
0
0
0
0
0
0
1
0
0
0
0
0
0
1
0
0
0
0
0
0
1
0
0
0
0
0
0
1
0
0
0
0
0
0
1
0
0
0
0
0
0
1
0
0
0
0
0
0
1
0
0
0
0
0
0
0
When track jump (shock) is detected
When ADER was counted more than five times
continuously
When ADIP address is not continuous
When DIN unlock is detected
When not in focus
When ABCD signal level exceeds the specified range
When CLV is unlocked
When access operation is not performed normally
Hexa-
decimal
shock
ader5
Discontinuous address
DIN unlock
FCS incorrect
IVR rec error
CLV unlock
Access fault
Cause of Retry
Occurring conditions
01
02
04
08
10
20
40
80
Reading the Display:
Convert the hexadecimal display into binary display. If more than two causes, they will be added.
Example
When 42 is displayed:
Higher bit : 4 = 0100 n b6
Lower bit : 2 = 0010 n b1
In this case, the retry cause is combined of “CLV unlock” and “ader5”.
When A2 is displayed:
Higher bit : A = 1010 n b7+b5
Lower bit : 2 = 0010 n b2
The retry cause in this case is combined of “access fault”, “IVR rec error”, and “ader5”.
Reading the Retry Cause Display
Page of 105
Display