Read Sony MDS-W1 Service Manual online
– 7 –
IOP DATA RECORDING AND DISPLAY WHEN PICKUP AND NON-VOLATILE MEMORY (IC171 OF BD BOARD)
ARE REPLACED
ARE REPLACED
The IOP value labeled on the pick-up can be recorded in the non-volatile memory. By recording the value, it will eliminate the need to look
at the value on the label of the optical pick-up. When replacing the pick-up or non-volatile memory (IC171 of BD board), record the IOP
value on the pick-up according to the following procedure.
at the value on the label of the optical pick-up. When replacing the pick-up or non-volatile memory (IC171 of BD board), record the IOP
value on the pick-up according to the following procedure.
For buttons or knobs not specified as (Deck A) or (Deck B) in the procedure, use that of the corresponding deck.
Record Precedure:
1. With the power ON, press the 0 (Deck B) button while pressing the OUTPUT and CLEAR (Deck A) buttons together.
2. Rotate the AMS knob to display “(Service)”, and press the YES button.
3. Rotate the AMS knob to display “lop.Write” (S: 28), and press the YES button.
4. The display becomes “Ref=@@@.@” (@ is an arbitrary number) and the numbers which can be changed will blink.
5. Input the IOP value written on the optical pick-up.
1. With the power ON, press the 0 (Deck B) button while pressing the OUTPUT and CLEAR (Deck A) buttons together.
2. Rotate the AMS knob to display “(Service)”, and press the YES button.
3. Rotate the AMS knob to display “lop.Write” (S: 28), and press the YES button.
4. The display becomes “Ref=@@@.@” (@ is an arbitrary number) and the numbers which can be changed will blink.
5. Input the IOP value written on the optical pick-up.
To select the number : Rotate the AMS knob.
To select the digit
To select the digit
: Press the AMS knob.
6. When the YES button is pressed, the display becomes “Measu=@@@.@” (@ is an arbitrary number).
7. As the adjustment results are recorded for the 6 value. Leave it as it is and press the YES button.
8. The value will be recorded in the non-volatile memory and the display will become “Iop Write”.
9. Press the MD SYNC button to complete.
7. As the adjustment results are recorded for the 6 value. Leave it as it is and press the YES button.
8. The value will be recorded in the non-volatile memory and the display will become “Iop Write”.
9. Press the MD SYNC button to complete.
Display Precedure:
1. With the power ON, press the 0 (Deck B) button while pressing the OUTPUT and CLEAR (Deck A) buttons together.
2. Rotate the AMS knob to display “(Service)”, and press the YES button.
3. Rotate the AMS knob to display “lop.Read” (S: 27).
4. “@@.@/##.#” is displayed and the recorded contents are displayed.
1. With the power ON, press the 0 (Deck B) button while pressing the OUTPUT and CLEAR (Deck A) buttons together.
2. Rotate the AMS knob to display “(Service)”, and press the YES button.
3. Rotate the AMS knob to display “lop.Read” (S: 27).
4. “@@.@/##.#” is displayed and the recorded contents are displayed.
@@.@ : indicates the Iop value labeled on the pick-up.
##.#
##.#
: indicates the Iop value after adjustment
5. To end, press the AMS button or MENU/NO button to display “Iop Read”. Then press the MD SYNC button.
Click on the first or last page to see other MDS-W1 service manuals if exist.