2-2 Dubbing Operation
The explanation that follows is for dubbing from deck A to deck B.
(1)
Analog Dubbing
The digital sound signals read at deck A are output from the DADT terminal (IC121; pin 26) of the DSP (digital
signal processing IC) for deck A to the main board’s D/A converter (IC331). The sound signals that have been
converted to analog signals are input to the A/D converter (IC461) by means of the jack board selectors (IC321 and
IC331) and converted to digital signals. These digital signals are input to the DADTI terminal (IC121; pin 22) of the
DSP for deck B through the selector (IC991), and the data is compressed and recorded on the MD in deck B.
For analog recording on deck B, the ADDT terminal (IC121; pin 25) for input from the A/D converter to the DSP
is not used.
(2)
Digital Dubbing
The music signals read from deck A are directly output from the DADT terminal (IC121; pin 26) of the DSP for
deck A to the DADTI terminal (pin 22) of the DSP for deck B and digital dubbing done.
(3)
MOVE
As for digital dubbing, the sound signals read from deck A are directly output from the DADT terminal (IC121;
pin 26) of the DSP for deck A to the DADTI terminal (pin 22) of the DSP for deck B. The data transmitted are
compressed sound signals that have not been subjected to ATRAC decoding.
In addition, the request signals of the dubbing data are output from the DIN1 terminal (pin 20) of the DSP for
deck B to the DIN1 terminal of the DSP for deck A. The DIN1 terminal is an input-output terminal, and for dubbing
in the reverse direction, the request signals are output in reverse.
In terms of monitor sound when MOVE function is used, sound sampled at a fixed interval from the DADTI
terminal (pin 22) of the DSP for deck A (same sound as for CUE operation) is subjected to 12dB attenuation and
output to the D/A converter (IC351). At this time, DADT terminal (pin 26), LRCK, BCK, etc., of the DSP for deck
B become high impedance so as not to obstruct monitor sound output.
Although regular MD recording is intermittent, with compressed data recorded for 0.5 seconds and then not
recorded for 1.5 seconds, when MOVE function is used, compressed data is recorded continuously, which allows
dubbing operations to be done at roughly quadruple speed.
2-3 Operation Clock
The 1024fs (45.158MHz) output from the crystal oscillator X3 is halved by IC306 and is input as the operation
clock to the OSCI terminal (pin 16) of the DSP for decks A and B. In addition, the 256fs that was the result of
quartering by IC306 is input to the D/A converter (IC331).
The clock input to the A/D converter's MCLK terminal (IC461; pin 17) of through the switch (IC311) is always
256fs. (512fs is not used.)