— 40 —
4-5. Temperature Compensation Offset Adjustment
Save the temperature data at that time in the non-volatile memory as
25 ˚C reference data.
Note :
1. Usually, do not perform this adjustment.
2. Perform this adjustment in an ambient temperature of 22 ˚C to 28
25 ˚C reference data.
Note :
1. Usually, do not perform this adjustment.
2. Perform this adjustment in an ambient temperature of 22 ˚C to 28
˚C. Perform it immediately after the power is turned on when the
internal temperature of the unit is the same as the ambient tem-
perature.
internal temperature of the unit is the same as the ambient tem-
perature.
3. When D101 has been replaced, perform this adjustment after the
temperature of this part has become the ambient temperature.
Adjusting Method :
1. Rotate the AMS knob and display “TEMP ADJUST”.
2. Press the ENTER/YES button and select the “TEMP ADJUST”
1. Rotate the AMS knob and display “TEMP ADJUST”.
2. Press the ENTER/YES button and select the “TEMP ADJUST”
mode.
3. “TEMP =
” and the current temperature data will be displayed.
4. To save the data, press the ENTER/YES button.
When not saving the data, press the EDIT/NO button.
5. When the ENTER/YES button is pressed, “TEMP =
SAVE”
will be displayed for some time, followed by “TEMP ADJUST”.
When the EDIT/NO button is pressed, “TEMP ADJUST” will be
displayed.
When the EDIT/NO button is pressed, “TEMP ADJUST” will be
displayed.
Specifications :
The “TEMP =
” should be within “E0 - EF”, “F0 - FF”, “00 - 0F”,
“10 - 1F” and “20 - 2F”.
4-6. Laser Power Adjustment
Connection :
Adjusting Method :
1. Set the laser power meter on the objective lens of the optical pickup.
1. Set the laser power meter on the objective lens of the optical pickup.
(When it cannot be set properly, press the
0 button or ) but-
ton and move the optical pickup.)
Connect the digital volt meter to TP (IOP) and TP (I+5V).
Connect the digital volt meter to TP (IOP) and TP (I+5V).
2. Rotate the AMS knob and display “LDPWRADJUST”.
(Laser power : For adjustment)
3. Press the ENTER/YES button twice and display “LD $ 4B = 3.5
mW”.
4. Adjust RV102 of the BD board so that the reading of the laser
power meter becomes 3.4
mW.
5. Press the ENTER/YES button and display “LD $ 96 = 7.0 mW”.
(Laser power:MO reading)
6. Check that the laser power meter and digital voltmeter readings
satisfy the specified value.
Specification :
Laser power meter reading : 7.0 ± 0.3 mW
Digital voltmeter reading : Optical pickup displayed value ± 10%
Digital voltmeter reading : Optical pickup displayed value ± 10%
(Optical pickup label)
+0.1
–0
–0
Laser power
meter
meter
Optical pick-up
objective lens
objective lens
Digital voltmeter
KMS
210A
27X40
B0825
B0825
n
lop = 82.5 mA in this case
lop (mA) = Digital voltmeter reading (mV)/ 1 (
lop (mA) = Digital voltmeter reading (mV)/ 1 (
Ω
)
7. Press the ENTER/YES button and display “LD $ 0F = 0.7 mW”.
(Laser power: MO reading)
8. Check that the laser power meter at this time satisfies the speci-
fied value.
Specification :
Laser power meter reading : 0.70 ± 0.1 mW
9. Press the EDIT/NO button and display “LDPWR ADJUST’, and
stop laser emission.
(The EDIT/NO button is effective at all times to stop the laser
emission.)
(The EDIT/NO button is effective at all times to stop the laser
emission.)
BD board
TP (I + 5V)
TP (IOP)
TP (I + 5V)
TP (IOP)