14
CD  SECTION
RF  SIGNAL  CHECK
Procedure:
1.  Connect the oscilloscope to TP (RF) and TP (VC) on the CD 
board.
2.  Insert the disc (PATD-012) (Part No. : 4-225-203-01).
3.  Press the [
u
] button.
4. Confi rm that the oscilloscope waveform is as shown in the fi g-
ure below. (eye pattern)
 
A good eye pattern means that the diamond shape (
◊) in the 
center of the waveform can be clearly distinguished.
•  RF signal reference waveform (eye pattern)
VOLT/DIV: 0.2 V (with the 10: 1 probe in use.)
TIME/DIV: 200 ns
0.7 to 1.7 Vp-p
When observing the eye pattern, set the oscilloscope 
for AC range and raise vertical sensitivity.
Connecting Location:
IC701
TP (VC) TP (RF)
– CD Board (Conductor Side) –