ICF-CD73, ICF-CD73V - Sony Audio Service Manual (repair manual). Page 16

Read Sony ICF-CD73 / ICF-CD73V Service Manual online

16
ICF-CD73/CD73V
CD SECTION
Perform all CD section check in the test mode.
FOCUS  BIAS  CHECK
Procedure:
1. Connect the oscilloscope to TP (RF) and TP (VC) on the CD
board.
2. Set the CD test mode. (Refer to CD TEST MODE (See page
11))
3. Insert the test disc (YEDS-18). (Part No. 3-702-101-01) (CD)
4. Press the 
[CD       ]
 button. (LPC ON)
5. Confirm that the oscilloscope waveform is as shown in the
figure below. (eye pattern)
A good eye pattern means that the diamond shape (
◊) in the
center of the waveform can be clearly distinguished.
6. Press the 
[CD       ]
button. (LPC OFF)
7. Perform confirmation in the same manner as step 5.
8. Press the 
[OFF    ]
 button.
9. Change the test disc (TCD-W082L). (Part No. J-2502-063-2)
(CD-RW)
10. Perform confirmation in the same manner as step 4 to 7.
• RF signal reference waveform (eye pattern)
Connecting Location:
VOLT/DIV: 0.2 V (with the 10: 1 probe in use.)
TIME/DIV: 500 ns
CD:
1.1 
±
 0.2 Vp-p (LPC ON)
1.1 
±
 0.3 Vp-p (LPC OFF)
CD-RW:
1.0 
±
 0.2 Vp-p (LPC ON)
0.9 
±
 0.3 Vp-p (LPC OFF)
When observing the eye pattern, set the oscilloscope 
for AC range and raise vertical sensitivity.
TP
(VC)
TP
(RF)
IC702
IC701
– CD BOARD (Conductor Side) –
TP
(TE)
x
NX
NX
Page of 54
Display