CD SECTION
CD section adjustments are done automatically in this set.
In case of operation check, confirm that focus bias.
Focus Bias Check
Connection:
Procedure:
1. Connect the oscilloscope to TP513 (RF) and TP568 (GND) on
the MAIN board.
2. Insert the disc (YEDS-18). (Part No. : 3-702-101-01)
3. Press the
u
button.
4. Confirm that the oscilloscope waveform is as shown in the
figure below. (eye pattern)
A good eye pattern means that the diamond shape ( ) in the
center of the waveform can be clearly distinguished.
• RF signal reference waveform (eye pattern)
Connecting Points: MAIN Board (See page 13)
MAIN board
TP513 (RF)
TP568 (GND)
+
oscilloscope
(AC range)
VOLT/DIV: 0.2 V (with the 10: 1 probe in use.)
TIME/DIV: 500 ns
1.2 
±
 0.2 Vp-p
When observing the eye pattern, set the oscilloscope 
for AC range and raise vertical sensitivity.